Chimney centrifugal fan VENTS KAM EcoDuo series

Chimney centrifugal fan VENTS KAM EcoDuo series

Chimney centrifugal fan for house heating system management using heat of chimney or fireplace. It can be also used as a base for backup heating source.

Series   Duct connection diameter   Motor   Modifications
VENTS КАМ   125; 140; 150; 160   EcoDuo - two-speed with external rotor   _ - is equipped with temperature regulator by default;
T1 -
without temperature regulator

 

Applications

Chimney fans for hot air distribution allow creating fully-featured air heating system based on a fireplace. Such system is the perfect solution for heating of seasonal houses that serve as a second residence during winter time and provides fast and efficient hot air distribution from chimney to other premises. Used for air distribution with the air tempreature range 0°С to +150°С.

Design

The fan casing is made of galvanized steel and equipped with heat- and sound insulation of fire-resistant mineral wool. The casing is perforated for the internal air circulation and motor cooling. The temperature regulator is used for setting the temperature level for the fan switching on and off. Fan startup is effected within the range of 0 °С to +90°С depending on the air temperature generated inside the fireplace heat-exchanger.

Motor

The fans are supplied with single-phase motors for operation in 230/50 Hz power supply network. Insulation Class F. The motors have built-in overheating protection with automatic restart. The motor is placed off-airflow and is equipped with forward-curved impeller blades as well as ball bearings for long service life.

  • The fan motors models marked KAM EcoDuo have two speeds and equipped with the external rotor.
Speed control

KAM EcoDuo fan speed is controlled by means of the speed switch.

Mounting

The fireplace fans are designed for connection with round air ducts. The fans can be mounted in any position with respect to the airflow direction indicated with a pointer on the casing. Access for the fan maintenance shall be reserved. Warm air feed ducts shall be laid between the fan and each of the heated rooms. Concealed air ducts system with forced warm air circulation allows saving useful space in the house and fits to the house design.

Accessories

FFK – removable G3 metal filter for boosted air purification. The filter is connected to the fan casing by lock-latches to provide easy removal of the filter for cleaning.


KFK – removable metal mixing chamber with incorporated thermal control damper and G3 filter for boosted air purification. The mixing set is fixed to the fan casing by means of lock-latches to ensure easy removal for cleaning. Fan configuration with KFK mixing chamber provides cool air supply into the mixing chamber when the operating temperature exceeds 90°С. Such configuration also allows hot air withdrawal while the fan motor is not running.


GFK
- gravitation backdraft damper to prevent air back draft in the system. Such fan configuration that includes KFK mixing chamber and GFK backdraft damper ensures fan motor overheating protection based on BY-PASS actuation, in particular when the motor is not running due to no power supply. The fans with such configuration enable backdraft damper shutting and hot air distribution to other premises through ventilation ducts when the motor is not running.

KAM EcoDuo fans operation principle

When air temperature in the fireplace hood reaches the set point, the fan turns automatically on and distributes hot air from the fire hood place to other premises. It turns off, when the temperature falls down below the set point.

Operation principle of KAM fan with FFK box filter

When air temperature in the fireplace hood reaches the set point, the fan turns automatically on and distributes purified through the FFK filter hot air from the fire hood place to other premises. It turns off, when the temperature falls down below the set point.


Operating logic of KAM filter with KFK mixing chamber and integrated heat control damper


When air temperature in the fireplace hood reaches the set point, the fan turns automatically on and distributes purified hot air from the fire hood place to other premises. It turns off, when air temperature falls down below the set point. The fan equipped with a mixing chamber provides cold air supply to the mixing chamber if the transported air temperature exceeds +90°С and hot air removal when the fan is off.

 

Operating logic of KAM filter with KFK mixing chamber and GFK gravity damper


When air temperature in the fireplace hood reaches the set point, the fan turns automatically on and distributes purified hot air from the fire hood place to other premises. It turns off, when the temperature falls down below the set point. The by-pass system is designed to prevent the fan overheating, i.e. during power failure. In this case GFK damper is closed and hot air is moved through the bypas air duct besides the fan. If the air supplied to the fan is too hot, the mixing chamber damper is opened to let cold air supply to the fan.

 

Installation and operation of KAM fans, KAM fans with FFK filter in the chimney system.

 

Installation and operation of KAM fans with KFK damper, KAM fans with KFK and GFK dampers according to BY-PASS system in the chimney system.

E-mail

Please, feel free to contact us.

support@vents.ua

Phohe

Customer service.

+380 44 406 36 25

Online form

Send a message center customer support.

By using this form you confirm that you have read and agree with the site condition and terms.
Send
  • External temperature regulator ТS-1-90

    External temperature regulator ТS-1-90

  • C series

    C series

  • CB series

    CB series