Mode Sound pressure level at 3 m distanceSound pressure level at 1 m distanceMountingConnected air duct diameterRemote control panelFunctionsHeatingTransported air temperatureAir capacitySEC ClassMax. unit current without electric heaterMax. unit power without electric heaterWeightHeat exchanger materialHeat exchanger typeHeat recovery efficiencyFilter: supplyFilter: extractInsulationCasing materialVoltagePhaseFrequencyMaximum unit current (with an electric heater)Electric preheater powerElectric reheater powerMaximum unit currentMax. unit current with electric heaterTurbine protection ratingRPMTypeSound-insulated casingOutdoor mountingIP CodeNoise level at 3 mEC motorPowerDesignFan currentPower consumptionSound pressure level at 3 mHeat exchanger typeElectric heater powerTransported air temperatureThe classification of the airflow sensitivity to pressure variations, according to EN 13141-8The classification of the indoor/outdoor air tightness, according to EN 13141-8Sound insulation according to DIN EN ISO 10140-2:2010Maximum unit powerMaximum transported air temperatureConnected air duct size
- 30 40 floor mounting 400 - Wi-Fi , Filter replacement indication , Timer , Weekly schedule , External sensor connection electric preheating -25 ... +40 1240 - 2.3 345 400 polystyrene counter-flow 84-96 ISO ePM1 60% (F7) ISO Coarse >60% (G4) 40 mm mineral wool polymer coated steel 400 3 50/60 12 3150 - - - - - - - - - - - - - - - - - - - - - - - - -
- 30 40 floor mounting 400 - Wi-Fi , Filter replacement indication , Timer , Weekly schedule , External sensor connection without heating -25 ... +40 1240 - 2.3 345 352 polystyrene counter-flow 84-96 ISO ePM1 60% (F7) ISO Coarse >60% (G4) 40 mm mineral wool polymer coated steel 230 1 50/60 2.3 - - - - - - - - - - - - - - - - - - - - - - - - - -
- 30 40 floor mounting 400 - Wi-Fi , Filter replacement indication , Timer , Weekly schedule , External sensor connection electric preheating , electric reheating -25 ... +40 1240 - 2.3 345 364 polystyrene counter-flow 84-96 ISO ePM1 60% (F7) ISO Coarse >60% (G4) 40 mm mineral wool polymer coated steel 400 3 50/60 18.7 3150 - - - - - - - - - - - - - - - - - - - - - - - - -
- 34 44 ceiling mounting 200 - Wi-Fi , Filter replacement indication , Timer , Weekly schedule , External sensor connection electric preheating -25 ... +40 300 A+ - 204 79 polystyrene counter-flow 83-92 ISO ePM1 60% (F7) ISO Coarse >60% (G4) - polymer coated steel 230 1 50/60 - 1050 - 1.5 7.7 - - - - - - - - - - - - - - - - - - - - - -
- 34 44 ceiling mounting 200 - Wi-Fi , Filter replacement indication , Timer , Weekly schedule , External sensor connection electric preheating , electric reheating -25 ... +40 300 A+ - 204 80 polystyrene counter-flow 83-92 ISO ePM1 60% (F7) ISO Coarse >60% (G4) - polymer coated steel 230 1 50/60 - 1050 700 1.5 11.7 - - - - - - - - - - - - - - - - - - - - - -
- 34 44 ceiling mounting 250 - Wi-Fi , Filter replacement indication , Timer , Weekly schedule , External sensor connection without heating -25 ... +40 510 A+ - 238 95 polystyrene counter-flow 83-96 ISO ePM1 60% (F7) ISO Coarse >60% (G4) - polymer coated steel 230 1 50/60 - - - 1.7 - - - - - - - - - - - - - - - - - - - - - - -
- 34 44 ceiling mounting 250 - Wi-Fi , Filter replacement indication , Timer , Weekly schedule , External sensor connection electric preheating -25 ... +40 510 A+ - 238 95 polystyrene counter-flow 83-96 ISO ePM1 60% (F7) ISO Coarse >60% (G4) - polymer coated steel 230 1 50/60 - 1050 - 1.7 9.3 - - - - - - - - - - - - - - - - - - - - - -
- 34 44 ceiling mounting 250 - Wi-Fi , Filter replacement indication , Timer , Weekly schedule , External sensor connection electric preheating , electric reheating -25 ... +40 510 A+ - 238 96 polystyrene counter-flow 83-96 ISO ePM1 60% (F7) ISO Coarse >60% (G4) - polymer coated steel 230 1 50/60 - 1050 700 1.7 12.6 - - - - - - - - - - - - - - - - - - - - - -
- 24 34 ceiling mounting 315 - Wi-Fi , Filter replacement indication , Timer , Weekly schedule , External sensor connection without heating -25 ... +40 1000 A+ - 267 252 polystyrene counter-flow 83-93 ISO ePM1 60% (F7) ISO Coarse >60% (G4) - polymer coated steel 230 1 50/60 - - - 1.85 - - - - - - - - - - - - - - - - - - - - - - -
- 24 34 ceiling mounting 315 - Wi-Fi , Filter replacement indication , Timer , Weekly schedule , External sensor connection electric preheating -25 ... +40 1000 A+ - 267 257 polystyrene counter-flow 83-93 ISO ePM1 60% (F7) ISO Coarse >60% (G4) - polymer coated steel 400 3 50/60 - 3150 - 1.85 12 - - - - - - - - - - - - - - - - - - - - - -
- 24 34 ceiling mounting 315 - Wi-Fi , Filter replacement indication , Timer , Weekly schedule , External sensor connection electric preheating , electric reheating -25 ... +40 1000 A+ - 267 268 polystyrene counter-flow 83-93 ISO ePM1 60% (F7) ISO Coarse >60% (G4) - polymer coated steel 400 3 50/60 - 3150 - 1.85 18 - - - - - - - - - - - - - - - - - - - - - -
- 34 44 ceiling mounting 200 - Wi-Fi , Filter replacement indication , Timer , Weekly schedule , External sensor connection without heating -25 ... +40 300 A+ - 204 78 polystyrene counter-flow 83-92 ISO ePM1 60% (F7) ISO Coarse >60% (G4) - polymer coated steel 230 1 50/60 - - - 1.5 - - - - - - - - - - - - - - - - - - - - - - -
- 34 44 ceiling mounting 200 - Wi-Fi , Filter replacement indication , Timer , Weekly schedule , External sensor connection without heating -25 ... +40 300 A+ - 204 78 polystyrene counter-flow 83-92 ISO ePM1 60% (F7) ISO Coarse >60% (G4) - polymer coated steel 230 1 50/60 - - - 1.5 - - - - - - - - - - - - - - - - - - - - - - -
- 34 44 ceiling mounting 200 - Wi-Fi , Filter replacement indication , Timer , Weekly schedule , External sensor connection electric preheating -25 ... +40 300 A+ - 204 79 polystyrene counter-flow 83-92 ISO ePM1 60% (F7) ISO Coarse >60% (G4) - polymer coated steel 230 1 50/60 - 1050 - 1.5 7.7 - - - - - - - - - - - - - - - - - - - - - -
- 34 44 ceiling mounting 250 - Wi-Fi , Filter replacement indication , Timer , Weekly schedule , External sensor connection without heating -25 ... +40 510 A+ - 238 95 polystyrene counter-flow 83-96 ISO ePM1 60% (F7) ISO Coarse >60% (G4) - polymer coated steel 230 1 50/60 - - - 1.7 - - - - - - - - - - - - - - - - - - - - - - -
- 34 44 ceiling mounting 250 - Wi-Fi , Filter replacement indication , Timer , Weekly schedule , External sensor connection electric preheating -25 ... +40 510 A+ - 238 95 polystyrene counter-flow 83-96 ISO ePM1 60% (F7) ISO Coarse >60% (G4) - polymer coated steel 230 1 50/60 - 1050 - 1.7 12.6 - - - - - - - - - - - - - - - - - - - - - -
- 34 44 ceiling mounting 250 - Wi-Fi , Filter replacement indication , Timer , Weekly schedule , External sensor connection electric preheating , electric reheating -25 ... +40 510 A+ - 238 96 polystyrene counter-flow 83-96 ISO ePM1 60% (F7) ISO Coarse >60% (G4) - polymer coated steel 230 1 50/60 - 1050 700 1.7 12.6 - - - - - - - - - - - - - - - - - - - - - -
- 34 44 ceiling mounting 200 - Wi-Fi , Filter replacement indication , Timer , Weekly schedule , External sensor connection electric preheating , electric reheating -25 ... +40 300 A+ - 204 80 polystyrene counter-flow 83-92 ISO ePM1 60% (F7) ISO Coarse >60% (G4) - polymer coated steel 230 1 50/60 - 1050 700 1.5 11.7 - - - - - - - - - - - - - - - - - - - - - -
- - - for roof - - - - -25 ... +60 770 - - - 6 - - - - - - polymer coated steel 230 1 50/60 - - - - - IP55 3538 exhaust no yes IP X4 52 yes 110 centrifugal 0.87 - - - - - - - - - - -
- - - for roof - - - - -25 ... +60 1350 - - - 7 - - - - - - polymer coated steel 230 1 50/60 - - - - - IP55 2478 exhaust no yes IP X4 47 yes 95 centrifugal 0.8 - - - - - - - - - - -
- - - for roof - - - - -25 ... +60 1500 - - - 8 - - - - - - polymer coated steel 230 1 50/60 - - - - - IP55 3310 exhaust no yes IP X4 54 yes 164 centrifugal 1.25 - - - - - - - - - - -
- - - for roof - - - - -25 ... +60 770 - - - 6 - - - - - - aluminium 230 1 50/60 - - - - - IP55 3538 exhaust no yes IP X4 52 yes 110 centrifugal 0.87 - - - - - - - - - - -
- - - for roof - - - - -25 ... +60 1350 - - - 7 - - - - - - aluminium 230 1 50/60 - - - - - IP55 2478 exhaust no yes IP X4 47 yes 95 centrifugal 0.8 - - - - - - - - - - -
- - - for roof - - - - -25 ... +60 1500 - - - 8 - - - - - - aluminium 230 1 50/60 - - - - - IP55 3310 exhaust no yes IP X4 54 yes 164 centrifugal 1.25 - - - - - - - - - - -
- - - - - - Wi-Fi , Filter replacement indication , Timer , Weekly schedule , Humidity sensor electric heating - 48 A - - - - - ≤ 90 - - - - - - - - - - - - - - supply and exhaust with heat recovery - - - - - - - - 8 40 Ceramic 160 -30...+50 S2 D2 40 - - -
- - - - - - Wi-Fi , Filter replacement indication , Timer , Weekly schedule , Humidity sensor , Carbon dioxide sensor , Air quality sensor electric heating - 48 A - - - - - ≤ 90 - - - - - - - - - - - - - - supply and exhaust with heat recovery - - - - - - - - 8 40 Ceramic 160 -30...+50 S2 D2 40 - - -
- - - - - - Wi-Fi , Filter replacement indication , Timer , Weekly schedule , Humidity sensor without heating - 48 A - - - - - ≤ 92 - - - - - - - - - - - - - - supply and exhaust with heat recovery - - - - - - - - 8 40 Ceramic - -30...+50 S2 D2 40 - - -
- - - - - - Wi-Fi , Filter replacement indication , Timer , Weekly schedule , Humidity sensor , Carbon dioxide sensor , Air quality sensor without heating - 48 A - - - - - ≤ 92 - - - - - - - - - - - - - - supply and exhaust with heat recovery - - - - - - - - 8 40 Ceramic - -30...+50 S2 D2 40 - - -
- 34 - - - - - - - 191 A+ - - 12 polystyrene counter-flow 91 G4 / Coarse > 60% (option F7 / ePM1 60%) G4 / Coarse > 60% 25 mm expanded polypropylene 230 1 50/60 - - - 0.46 - - - - - - - - - - - - - - - - - - - - 54 45 160
- 34 - - - - - - - 191 A - - 15 enthalpy counter-flow 82 G4 / Coarse > 60% (option F7 / ePM1 60%) G4 / Coarse > 60% 25 mm expanded polypropylene 230 1 50/60 - - - 0.46 - - - - - - - - - - - - - - - - - - - - 54 45 160
- 34 - - - - - - - 191 A+ - - 12 polystyrene counter-flow 91 G4 / Coarse > 60% (option F7 / ePM1 60%) G4 / Coarse > 60% 25 mm expanded polypropylene 230 1 50/60 - - - 0.46 - - - - - - - - - - - - - - - - - - - - 54 45 160
- 34 - - - - - - - 191 A - - 15 enthalpy counter-flow 82 G4 / Coarse > 60% (option F7 / ePM1 60%) G4 / Coarse > 60% 25 mm expanded polypropylene 230 1 50/60 - - - 0.46 - - - - - - - - - - - - - - - - - - - - 54 45 160
- 35 - - - - - - - 313 A - - 13 polystyrene counter-flow 90 G4 / Coarse > 60% (option F7 / ePM1 60%) G4 / Coarse > 60% 25 mm expanded polypropylene 230 1 50/60 - - - 1.3 - - - - - - - - - - - - - - - - - - - - 168 45 160
- 35 - - - - - - - 313 A - - 16 enthalpy counter-flow 79 G4 / Coarse > 60% (option F7 / ePM1 60%) G4 / Coarse > 60% 25 mm expanded polypropylene 230 1 50/60 - - - 1.3 - - - - - - - - - - - - - - - - - - - - 168 45 160
- 35 - - - - - - - 313 A - - 13 polystyrene counter-flow 90 G4 / Coarse > 60% (option F7 / ePM1 60%) G4 / Coarse > 60% 25 mm expanded polypropylene 230 1 50/60 - - - 1.3 - - - - - - - - - - - - - - - - - - - - 168 45 160
- 35 - - - - - - - 313 A - - 16 enthalpy counter-flow 79 G4 / Coarse > 60% (option F7 / ePM1 60%) G4 / Coarse > 60% 25 mm expanded polypropylene 230 1 50/60 - - - 1.3 - - - - - - - - - - - - - - - - - - - - 168 45 160
- 34 - - - - - - - 191 A - - 15 enthalpy counter-flow 82 G4 / Coarse > 60% (option F7 / ePM1 60%) G4 / Coarse > 60% 25 mm expanded polypropylene 230 1 50/60 - - - 0.46 - - - - - - - - - - - - - - - - - - - - 54 45 160
- 34 - - - - - - - 191 A+ - - 12 polystyrene counter-flow 91 G4 / Coarse > 60% (option F7 / ePM1 60%) G4 / Coarse > 60% 25 mm expanded polypropylene 230 1 50/60 - - - 0.46 - - - - - - - - - - - - - - - - - - - - 54 45 160
- 34 - - - - - - - 191 A+ - - 12 polystyrene counter-flow 91 G4 / Coarse > 60% (option F7 / ePM1 60%) G4 / Coarse > 60% 25 mm expanded polypropylene 230 1 50/60 - - - 0.46 - - - - - - - - - - - - - - - - - - - - 54 45 160
- 34 - - - - - - - 191 A - - 15 enthalpy counter-flow 82 G4 / Coarse > 60% (option F7 / ePM1 60%) G4 / Coarse > 60% 25 mm expanded polypropylene 230 1 50/60 - - - 0.46 - - - - - - - - - - - - - - - - - - - - 54 45 160
- 35 - - - - - - - 313 A - - 13 polystyrene counter-flow 90 G4 / Coarse > 60% (option F7 / ePM1 60%) G4 / Coarse > 60% 25 mm expanded polypropylene 230 1 50/60 - - - 1.3 - - - - - - - - - - - - - - - - - - - - 168 45 160
- 35 - - - - - - - 313 A - - 16 enthalpy counter-flow 79 G4 / Coarse > 60% (option F7 / ePM1 60%) G4 / Coarse > 60% 25 mm expanded polypropylene 230 1 50/60 - - - 1.3 - - - - - - - - - - - - - - - - - - - - 168 45 160
- 35 - - - - - - - 313 A - - 13 polystyrene counter-flow 90 G4 / Coarse > 60% (option F7 / ePM1 60%) G4 / Coarse > 60% 25 mm expanded polypropylene 230 1 50/60 - - - 1.3 - - - - - - - - - - - - - - - - - - - - 168 45 160
- 35 - - - - - - - 313 A - - 16 enthalpy counter-flow 79 G4 / Coarse > 60% (option F7 / ePM1 60%) G4 / Coarse > 60% 25 mm expanded polypropylene 230 1 50/60 - - - 1.3 - - - - - - - - - - - - - - - - - - - - 168 45 160
Share your opinion