Vents VVR 180

Vents VVR 180
Vents VVR 180
  • Fan ON - louver shutters OPEN.
  • Fan OFF - louver shutters CLOSED.

Maximum capacity - 212 m3/h.

Products in this series  (1)

  • Vents VVR 230

    Vents VVR 230

  • Window flange FO series

    Window flange FO series

  • Electrical accessories

    Electrical accessories


ParameterValueUnit
Mode
exhaust;supply
Voltage
220-240
V
Frequency
50/60
Hz
Power
25
W
Air capacity
212  /  176
124,868  /  103,664
58,936  /  48,928
0,05894  /  0,04893
3540,4  /  2939,2
m³/h
CFM
l/s
m³/s
l/m
Current
0.1
A
RPM
1400
min -1
Sound pressure level at 3 m
31
[dBA]
Weight
1.6
kg
Protection rating
IP 24
class
Spigot size
180
mm
Engine Type
220-240V / 50-60Hz
Vents VVR 180
SizesABCD
mm2306587177

E-mail

Please, feel free to contact us.

support@vents.ua

Phohe

Customer service.

+380 44 406 36 25

Online form

Send a message center customer support.


By using this form you confirm that you have read and agree with the site condition and terms.
Send
  • Selection method:
  • Performance:
  • Pressure:
Duty point
  • Performance:- -
  • Pressure:- -
  • Power:- -
  • Recovery Efficiency:- -

1 - air supply
2 - air exhaust

Wiring diagram for the fans equipped with a built-in switch Wiring diagram for the fans without built-in switch
Wiring diagram for the fans equipped with a timer / timer, humidity sensor and a built-in switch Wiring diagram for the fans equipped with a timer / timer with a humidity sensor without built-in switch
Wiring diagram for the fans with a light lamp. Separate activation of the fan and the built-in lamp. Wiring diagram for the fans with a light lamp. Parallel activation of the fan and the built-in lamp.
Wiring diagram for the fans with an light lamp and grounding. Separate activation of the fan and the built-in lamp. Wiring diagram for the fans with a light lamp and grounding. Parallel switching of the fan and the built-in lamp.
Wiring diagram for the fans with grounding  
 

* - only for fans designed for 12 V rated voltage (specified on the fan casing and packing).
S, S1, S2 - external switches.

Operating logic of the fans with optional equipment
  • The fan equipped with a timer is activated by the control voltage supplied to LT input. After the control voltage is disconnected the fan continues operating within the time period within 2 to 30 minutes according to the timer settings. The turn-off delay time is adjusted by turning the respective potentiometer T control knob clockwise to increase and counter-clockwise to reduce it.
  • The fan equipped with a timer and humidity sensor is activated by the control voltage supplied to LT input or in case of exceeding the preset humidity threshold value adjustable from ~60% to ~90%. After the control voltage is disconnected or as the humidity level H drops below the set threshold the fan continues operating within the time period within 2 to 30 minutes according to the timer settings.  The turn-off delay time and the threshold humidity level are adjusted by turning the control knob of the respective potentiometer T for timer and H for humidity sensor clockwise to increase and counter-clockwise to reduce the set value. To set the maximum humidity level (90%) set the potentiometer control knob for H max position.
  • The fan equipped with a timer and motion sensor is activated in case of the moving detection at the distance from 1 m to 4 m with 100° detection angle. After motion is off the fan continues operating within the time period within 2 to 30 minutes according to the timer settings. The turn-off delay time is adjusted by turning the respective potentiometer T control knob clockwise to increase and counter-clockwise to reduce it.
  • Wiring diagram for connection of the light lamp to the fan timer operated by the common switch is shown on diagram 4. Upon the light lamp disconnection the fan continues operating according to the timer setting within the set time period.