TT PRO 150*
Inline mixed flow fan. Maximum capacity - 565 m3/h.
* Compliant to the ErP-regulation (EC) 327/2011, the power consumption at optimum efficiency is < 125W.
Parameter | Value | Unit | |
---|---|---|---|
Speed | min / max | ||
Phase | 1 | ˜ | |
Voltage | 230 | V | |
Frequency | 50 / 60 | Hz | |
Current | 0.19 / 0.22 | A | |
Power consumption | 42 / 50 | W | |
Maximum air capacity | 415 / 565 244,435 / 332,785 115,37 / 157,07 0,11537 / 0,15707 6930,5 / 9435,5 | m³/h CFM l/s m³/s l/m | |
RPM | 1940 / 2620 | min -1 | |
Noise level at 3 m | 37 / 46 | [dBA] | |
Maximum transported air temperature | 60 | оC | |
Protection rating | IP X4 | class | |
Weight | 2.3 | kg | |
Spigot size | 150 | mm | |
High-powered motor | no | ||
SEC Class | B |
Sizes | ØD | B | H | L |
---|---|---|---|---|
mm | 148 | 220.1 | 247 | 289 |
Phohe
Customer service.
+380 44 406 36 25
Online form
Send a message center customer support.
- Selection method:
- Performance:
- Pressure:
Duty point
- Performance:- -
- Pressure:- -
- Power:- -
- Recovery Efficiency:- -
Sound power level, A-filter applied | Sound pressure level at 3 meters, A-filter applied | Sound pressure level at 1 meters, A-filter applied | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Sound-power level, A - weighted | general | Octave frequency band, Hz | ||||||||||||||||||||
Hz | 63 | 125 | 250 | 500 | 1000 | 2000 | 4000 | 8000 | LpA, 1m[dB(A)] | LpA, 1m[dB(A)] | ||||||||||||
Min speed | ||||||||||||||||||||||
LwA to inlet | dB(A) | 64 | 26 | 38 | 63 | 55 | 56 | 51 | 41 | 27 | 44 | 54 | ||||||||||
LwA to outlet | dB(A) | 64 | 25 | 37 | 62 | 54 | 55 | 50 | 40 | 27 | 43 | 53 | ||||||||||
LwA to environment | dB(A) | 54 | 18 | 30 | 52 | 46 | 47 | 43 | 35 | 23 | 34 | 44 | ||||||||||
Max speed | ||||||||||||||||||||||
LwA to inlet | dB(A) | 75 | 33 | 44 | 71 | 67 | 65 | 70 | 56 | 42 | 54 | 64 | ||||||||||
LwA to outlet | dB(A) | 74 | 32 | 43 | 70 | 65 | 64 | 70 | 54 | 42 | 54 | 64 | ||||||||||
LwA to environment | dB(A) | 64 | 24 | 35 | 59 | 56 | 55 | 60 | 47 | 35 | 43 | 53 |