Vote

Basic parameter for domestic fan selection

Keep up with us

RSS Subscribe to blog
Vents.TV

Blog messages

Go to blog

ТТ PRO 200*

ТТ PRO 200*
ТТ PRO 200*
  • TT fan with a three-position speed switch.
  • TT fan with a built-in speed controller.
  • TTP kit for parallel connection.
  • TTS kit for series connection.
  • Temperature sensor integrated inside a fan duct (U/U1 option).
  • External temperature sensor fixed on 4 m power cable (Un / U1n option).

Inline mixed flow fan. Maximum capacity - 1040 m3/h.

  • SR series (round)

    SR series (round)

  • FB series (round)

    FB series (round)

  • KOM series

    KOM series

  • NKV series (round)

    NKV series (round)

  • NK series (round)

    NK series (round)

  • Temperature regulator RTS and RTSD

    Temperature regulator RTS and RTSD

  • Switch P...-5,0 N(V)

    Switch P...-5,0 N(V)

  • C series

    C series

  • Switch P...-1-300

    Switch P...-1-300

  • FBK series (round)

    FBK series (round)

  • KR series (round)

    KR series (round)

* Compliant to the ErP-regulation (EC) 327/2011, the power consumption at optimum efficiency is < 125W.
ParameterValueUnit
Speed
min  /  max
Phase
1
˜
Voltage
230
V
Frequency
50 / 60
Hz
Current
0.34  /  0.48
A
Power consumption
76  /  108
W
Maximum air capacity
830  /  1040
488,87  /  612,56
230,74  /  289,12
0,23074  /  0,28912
13861  /  17368
m³/h
CFM
l/s
m³/s
l/m
RPM
1915  /  2380
min -1
Noise level at 3 m
45  /  52
[dBA]
Maximum transported air temperature
60
оC
Protection rating
IP X4
class
Weight
3.95
kg
Spigot size
200
mm
High-powered motor
no
SEC Class
E
ТТ PRO 200*
SizesØDBHL
mm199239261295.5

E-mail

Please, feel free to contact us.

support@vents.ua

Phohe

Customer service.

+380 44 406 36 25

Online form

Send a message center customer support.


By using this form you confirm that you have read and agree with the site condition and terms.
Send
  • Selection method:
  • Performance:
  • Pressure:
Duty point
  • Performance:- -
  • Pressure:- -
  • Power:- -
  • Recovery Efficiency:- -
Sound power level, A-filter applied  Sound pressure level at 3 meters, A-filter appliedSound pressure level at 1 meters, A-filter applied
Sound-power level, A - weighted   general   Octave frequency band, Hz  
  Hz     63   125   250   500   1000   2000   4000   8000  LpA, 1m[dB(A)]LpA, 1m[dB(A)]
Min speed
LwA to inlet dB(A)   73  36   49   64  65   69  67   56   42   52 62
LwA to outlet dB(A)   71  35   47   63  64   67   66   56   42   51 62
LwA to environment dB(A)   60   24   36   50   52   55   54  46   34   39 49
Max speed
LwA to inlet dB(A)  78   38   50   69   70   74   73   65   51   57 67
LwA to outlet dB(A)   77   36   49   68   69   72   72   63   49   5666
LwA to environment dB(A)   65   26   38   55   57   60   60   53   41   44 54