Vote

How often do you use equipment selection program?

Keep up with us

RSS Subscribe to blog
Vents.TV

Blog messages

Go to blog

Vents 125 MAO2 turbo

Vents 125 MAO2 turbo
Vents 125 MAO2 turbo
  • Back side of МАО2 fan.
  • 3d

Maximum capacity - 232 m3/h.

Voltage / frequency:

OK

Products in this series  (4)

    • Vents 125 MAO2

      Vents 125 MAO2

      Maximum capacity - 185 m3/h.

      Vents 125 MAO2 12

      Vents 125 MAO2 12

      Maximum capacity - 165 m3/h.

      Vents 125 МАО2 (220/60)

      Vents 125 МАО2 (220/60)

      Maximum capacity - 161.4 m3/h.

      Vents 125 МАО2 (120/60)

      Vents 125 МАО2 (120/60)

      Maximum capacity - 142.72 m3/h.

    Add to a projectVENTS 125 MAO2 turbo
    Add to a projectVENTS 125 MAO2T turbo
    Add to a projectVENTS 125 MAO2V turbo
    Add to a projectVENTS 125 MAO2VT turbo
    Add to a projectVENTS 125 MAO2 L turbo
    Add to a projectVENTS 125 MAO2T L turbo
    Add to a projectVENTS 125 MAO2V L turbo
    Add to a projectVENTS 125 MAO2VT L turbo
    • Timer
    • Back valve
    • Long-lasting BB (Ball Bearing) Motors
    • Pull-cord switch
    • More powerful motors
    • Humidity sensor
    • High pressure
    • Infrared sensor
    • Low voltage (12 V)
    • High-powered motor
    • Electrical accessories

      Electrical accessories


    ParameterValueUnit
    Voltage
    220-240
    V
    Frequency
    50/60
    Hz
    Power
    24
    W
    Air capacity
    232
    136,648
    64,496
    0,0645
    3874,4
    m³/h
    CFM
    l/s
    m³/s
    l/m
    Current
    0.105
    A
    RPM
    2400
    min -1
    Sound pressure level at 3 m
    37
    [dBA]
    Weight
    1.24
    kg
    Protection rating
    IP 24
    class
    Spigot size
    125
    mm
    Engine Type
    220-240V / 50-60Hz
    SEC Class
    E
    Vents 125 MAO2 turbo
    SizesBHH1L1L2
    mm19017316058123

    E-mail

    Please, feel free to contact us.

    support@vents.ua

    Phohe

    Customer service.

    +380 44 406 36 25

    Online form

    Send a message center customer support.


    By using this form you confirm that you have read and agree with the site condition and terms.
    Send
    • Selection method:
    • Performance:
    • Pressure:
    Duty point
    • Performance:- -
    • Pressure:- -
    • Power:- -
    • Recovery Efficiency:- -
    Wiring diagram for the fans equipped with a built-in switch Wiring diagram for the fans without built-in switch
    Wiring diagram for the fans equipped with a timer / timer, humidity sensor and a built-in switch Wiring diagram for the fans equipped with a timer / timer with a humidity sensor without built-in switch
    Wiring diagram for the fans with a light lamp. Separate activation of the fan and the built-in lamp. Wiring diagram for the fans with a light lamp. Parallel activation of the fan and the built-in lamp.
    Wiring diagram for the fans with an light lamp and grounding. Separate activation of the fan and the built-in lamp. Wiring diagram for the fans with a light lamp and grounding. Parallel switching of the fan and the built-in lamp.
    Wiring diagram for the fans with grounding  
     

    * - only for fans designed for 12 V rated voltage (specified on the fan casing and packing).
    S, S1, S2 - external switches.

    Operating logic of the fans with optional equipment
    • The fan equipped with a timer is activated by the control voltage supplied to LT input. After the control voltage is disconnected the fan continues operating within the time period within 2 to 30 minutes according to the timer settings. The turn-off delay time is adjusted by turning the respective potentiometer T control knob clockwise to increase and counter-clockwise to reduce it.
    • The fan equipped with a timer and humidity sensor is activated by the control voltage supplied to LT input or in case of exceeding the preset humidity threshold value adjustable from ~60% to ~90%. After the control voltage is disconnected or as the humidity level H drops below the set threshold the fan continues operating within the time period within 2 to 30 minutes according to the timer settings.  The turn-off delay time and the threshold humidity level are adjusted by turning the control knob of the respective potentiometer T for timer and H for humidity sensor clockwise to increase and counter-clockwise to reduce the set value. To set the maximum humidity level (90%) set the potentiometer control knob for H max position.
    • The fan equipped with a timer and motion sensor is activated in case of the moving detection at the distance from 1 m to 4 m with 100° detection angle. After motion is off the fan continues operating within the time period within 2 to 30 minutes according to the timer settings. The turn-off delay time is adjusted by turning the respective potentiometer T control knob clockwise to increase and counter-clockwise to reduce it.
    • Wiring diagram for connection of the light lamp to the fan timer operated by the common switch is shown on diagram 4. Upon the light lamp disconnection the fan continues operating according to the timer setting within the set time period.