VENTS M1 Series
Axial fans for exhaust ventilation with the capacity up to 345 m3/h. Compatible with 100, 125 or 150 mm air ducts.
Voltage / frequency: |
Products in this series (12)
CE mark means that the equipment is produced in compliance with the quality and safety standards provided by EU regulations for the given product type (marked by manufacturer). | |
Mark of conformity to the European Quality Standards and Electrical Safety issued by Association for Technical Inspection (Technischer Überwachungsverein, Germany). | |
Mark of conformity to the Polish Quality Standards and electrical safety issued by PCBC (Polish center for testing and certification). | |
Mark of conformity to the Slovak Quality Standards and electrical safety issued by EVPU (Slovakia). | |
Mark of conformity to the Ukrainian Quality Standards and electrical safety issued by UkrTEST. | |
Mark of conformity of the goods subject to obligatory certification in DSTR system as well as technical norms and standards acting in Russian Federation. Confirmed by the RosTEST certificates (Moscow). | |
Insulation class: double insulation. | |
Equipment protection rating. |
Picture symbol | Designation | Modification description | ||
---|---|---|---|---|
M1 К | Fan is equipped with a backdraft damper for back flow preventing. | |||
M1 L | The motor is equipped with ball bearings for long service life (appr. 40 thousand hours) and fan mounting at any angle. The bearings are maintenance-free and contain enough grease for the entire operating period. | |||
М1 turbo | High-powered motor. | |||
M1 press | 5-blade low-noise impeller with improved aerodynamics for higher fan capacity. | |||
М1 12 | Modification with low-voltage motor. 12 V AC power supply. | |||
M1T | Equipped with a regulated timer with the operating time from 2 to 30 minutes. | |||
M1TH | Equipped with a timer with the operating time from 2 to 30 minutes and a humidity sensor with the threshold value from 60 to 90%. | |||
M1V | Equipped with a pull cord switch. | |||
М1VТ | Equipped with a pull cord switch and a regulated timer with the operating time adjustable from 2 to 30 minutes. | |||
M1VТН | Equipped with a pull cord switch, regulated timer with the operating time adjustable from 2 to 30 minutes and a humidity sensor with the operating threshold range from 60% to 90%. | |||
М1ТР | Equipped with a regulated timer and a motion sensor with the sensitivity area from 1 to 4 m and the detection angle up to 100°). |
Applications
- Continuous or periodic exhaust ventilation of bathroom, showers, kitchens and other utility spaces.
- Ventilation shaft mounting or duct connection.
- Low to medium air flow motion for short distances at low air resistance.
- Compatible with 100, 125 and 150 mm air ducts.
Design
- Modern design and aesthetic look.
- The casing and the impeller are made of high-quality durable ABS plastic, UV resistant.
- The intellectual impeller design makes the fan efficiency high and the service life long.
- Insect screen.
- Protection rating IP 34.
Motor
- Reliable and low-watt electric motor.
- Designed for continuous operation and requires no maintenance.
- Equipped with overheating protection.
Control
Manual:
- The fan is controlled by a room light switch. It is not included in the delivery package.
- The fan is controlled by the built-in pull cord switch V. Not applied in case of ceiling mounting.
- Speed control is possible through a thyristor speed controller (see Electrical Accessories). Several fans may connected to the same controller. Speed controllers can not be connected to the fans with T, TH, TP, VT, VTH modification.
Automatic:
- By the electronic control unit BU-1-60 (see Electrical Accessories). The control unit is supplied separately.
- By the timer T (the built-in run-out timer enables the fan operation within 2 to 30 minutes after the fan switching off).
- By the humidity sensor and timer TH (if the humidity level in the room exceeds the sensor threshold adjustable value within 60-90% the fan switches automatically on and operates until the humidity level drops to the standard level, after that the fan continues operating within the time period according to the timer setting, then shuts down).
- By the motion sensor and the timer TP (in case of motion detection the fan switches automatically on and operates within the set time period from 2 to 30 minutes. The motion sensitivity area is up to 4 meters and the maximum detection angle is 100°.
Mounting features
- The fan is mounted directly into the ventilation shaft.
- Flexible duct application is recommended in case of remote location of the ventilation shaft. The air duct is connected to the fan exhaust flange through a clamp.
- Fixed to the wall by self-tapping screws.
- For 12 V low-voltage motor fan connection to 220 V / 50 Hz power mains use the step-down transformer TRF 220/12-25 that is available upon separate order.
Mounting example
Phohe
Customer service.
+380 44 406 36 25
Online form
Send a message center customer support.
- Selection method:
- Performance:
- Pressure:
Thank your for your time and your wish to improve our site.