VUE 900 EH EC ECO
Maximum capacity - 940 m3/h.
Voltage / frequency: |
Products in this series (11)
*modification
Parameter | Value | Unit | |
---|---|---|---|
Phase | 1 | ˜ | |
Unit voltage | 230 | V | |
Frequency | 50/60 | Hz | |
Max. unit power without electric heater | 340 | W | |
Max. unit current without electric heater | 2.2 | A | |
Integrated electric heater power | 3000 | W | |
Integrated electric heater current | 13 | A | |
Maximum air capacity | 940 553,66 261,32 0,26132 15698 | m³/h CFM l/s m³/s l/m | |
RPM | 1740 | min -1 | |
Sound pressure level at 3 m | 28-47 | [dBA] | |
Casing material | aluzinc | ||
Maximum transported air temperature | -25 +60 | оC | |
Insulation | 25 mm, mineral wool | ||
Connected air duct size | 250 | mm | |
Filter: extract | G4 | ||
Filter: supply | G4 | ||
Heat recovery efficiency | 74-94 | up to % | |
Heat exchanger type | counter-flow | ||
ЕС- motor | yes | ||
Type | air handling units with heat recovery | ||
SEC Class | A |
Sizes | ∅D | B | B1 | B2 | B3 | H | H1 | H2 | L | L1 |
---|---|---|---|---|---|---|---|---|---|---|
mm | 249 | 940 | 250 | 837 | 345 | 620 | 262 | 156 | 1200 | 1282 |
Phohe
Customer service.
+380 44 406 36 25
Online form
Send a message center customer support.
- Selection method:
- Performance:
- Pressure:
Duty point
- Performance:- -
- Pressure:- -
- Power:- -
- Recovery Efficiency:- -
Point | Unit single power [W] |
---|---|
1 | 340 |
2 | 340 |
3 | 336 |
4 | 300 |
5 | 138 |
6 | 140 |
7 | 120 |
8 | 110 |
9 | 33 |
10 | 32 |
11 | 32 |
12 | 28 |
A-weighted sound power level | Octave-frequency band [Hz] | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
General | 63 | 125 | 250 | 500 | 1000 | 2000 | 4000 | 8000 | LpA, 3 m dB(A) | LpA, 1 m dB(A) | ||||||||||||
LwAto supply air inlet | dB(A) | 36 | 55 | 51 | 41 | 47 | 42 | 38 | 28 | 29 | ||||||||||||
LwA to supply air outlet | dB(A) | 47 | 62 | 62 | 59 | 53 | 52 | 42 | 29 | 35 | ||||||||||||
LwAto exhaust air inlet | dB(A) | 36 | 54 | 51 | 42 | 48 | 41 | 37 | 29 | 29 | ||||||||||||
LwA to exhaust air outlet | dB(A) | 46 | 60 | 63 | 60 | 52 | 52 | 41 | 27 | 32 | ||||||||||||
LwA surrounding | dB(A) | 26 | 29 | 36 | 32 | 24 | 22 | 26 | 26 | 22 | 24 | 34 |