VENTS Quiet Extra 150


Maximum capacity - 370 m3/h.

3D model
Gallery
  • Description
  • Characteristics
  • Capacity diagram
  • Downloads
  • Modifications
  • Dimensions
  • Designation key
  • Video
Description
Description
APPLICATIONS  
  • Innovative exhaust fan with stylish design for new comfort level in shower rooms, bathrooms, kitchens and other residential premises.
  • Maximum air capacity combined with low noise level provide the ideal microclimate.
  • Mounting into ventilation shafts or connection to Ø100, 125, 150 mm.
DESIGN  
  • Casing and impeller made of high-quality and durable UV-resistant plastic.
  • Specially designed impeller aerodynamic profile provides high air capacity and low noise.
  • The compact design enables wall and ceiling mounting.
  • The shortened spigot for mounting into a ventilation shaft or connection to Ø 100, 125, 150 mm air ducts.
  • The fan is equipped with a specially designed back valve to prevent back flow and heat losses during the fan standby.
  • The fan exhaust spigot incorporates specially designed air rectifiers to reduce air turbulence, increase air pressure and lower noise level.
  • High ingress protection rating ensures makes the fan the ideal solution for ventilation of a bathroom. The electronic components are protected with tight covers. Models VENTS 150 Quiet and VENTS 150 Quiet Extra are additionaly equipped with a special vibration absorbing sealer along the fan countour.
MOTOR  
  • Low energy demand from 7.5 W due to new high-efficient motor.
  • Maintenance-free bearings contain enough grease for 40 000 hrs non-stop operation.
  • Motor on special anti-vibration dampers for vibration absorbing and silent operation.
  • Motor equipped with overheating protection.
  • VENTS 150 Quiet supplied with 2 speed motor. VENTS 150 Quiet Extra supplied with 2 speed high powered motor.
Operation modes of the VENTS 150 Quiet and VENTS 150 Quiet Extra
 Operation modes of the fans models VENTS 150 Quiet and VENTS 150 Quiet Extra with modifications TTHVTVTHTP is selected by setting the DIP switch into the required position. 
 Mode 1 (single-speed mode)
  • The fan is turned off by default. The fan starts operating at the 1st speed when the switch is closed or one of the sensors is activated.

Mode 2 (single-speed mode)

  • The fan is turned off by default. The fan starts operating at the 2nd speed when the switch is closed or the sensors are activated.

Mode 3 (two-speed mode)

  • The fan operates at the 1st speed by default. The fan switches to the 2nd speed when the switch is closed or the sensors are activated.
 Mode 4 (two-speed mode)
  • The fan is turned off by default. The fan starts operating at the 1st speed when the switch is closed and switches to the 2nd speed when the humidity sensor is activated.

Mode 5 (two-speed mode)

  • The fan is turned off by default. The fan starts operating at the 1st speed when the switch is closed or when the humidity sensor is activated. If during the operation at the 1st speed the second even takes place. i.e. the switch is closed or the humidity sensor is activated, the fan switches to the 2nd speed.
CONTROL  

Manual control:

  • Manual control with a room light switch. The switch is not included into delivery set.
  • The fan is controlled by the built-in pull cord switch V. Not applied in case of ceiling mounting.
  • Speed control is possible through a thyristor speed controller or through speed switch P2-1-300 (only for VENTS 150 Quiet models), see Electrical Accessories. Several fans may connected to the same controller. Speed controllers can not be connected to the fans with TTHTPVTVTH modification.

Automatic control:

  • By the electronic control unit BU-1-60 ( see Electrical Accessories). The control unit is supplied separately.
  • By the timer T (the built-in run-out timer enables the fan operation within 2 to 30 minutes after the fan switching off).
  • By the humidity sensor and timer TH (if the humidity level in the room exceeds the sensor threshold within 60-90% the fan switches automatically on and operates until the humidity level drops to the standard level, after that the fan continues operating within the set time period and shuts down).
  • By the motion sensor and timer TP (if motion is detected in the reach area, the fan is switched automatically and operates within the set time period from 2 to 30 min). Reach distance up to 4 m, the max. viewing angle 100°.

MOUNTING FEATURES

 
  • Installation directly inside a ventilation shaft.
  • Flexible air ducts may be used in case of remote location of the ventilation shaft.
  • Connection of the air duct to the exhaust flange with a clamp.
  • Wall mounting with screws.
  • Suitable for ceiling mounting.