Mode DesignMountingCasing materialDuctDuct diameterFrequency Power consumptionSound pressure level at 3 m distanceProtection ratingSEC ClassCurrentWeightVoltageRPMMaximum air capacity Max. transported air temperature*CurrentRPMSound- and heat-insulated casing PowerPhaseNumber of polesTypeMaximum air capacityMotor protection ratingCurrentTransported air temperatureCurrentVoltageFrequencyPower consumptionAir capacitySound pressure level at 3 mWeightIP CodeAir capacityCurrentSpigot sizeRPM
min mixed-flow Inline plastic for round air ducts 150 50/60 42 37 IP X4 B 0.19 2.3 1~230 1940 415 60 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). - - - - - - - - - - - - - - - - - - - - - - -
max mixed-flow Inline plastic for round air ducts 150 50/60 50 46 IP X4 B 0.22 2.3 1~230 2620 565 60 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). - - - - - - - - - - - - - - - - - - - - - - -
min mixed-flow Inline plastic for round air ducts 200 50/60 76 45 IP X4 B 0.34 3.95 1~230 1915 830 60 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). - - - - - - - - - - - - - - - - - - - - - - -
max mixed-flow Inline plastic for round air ducts 200 50/60 108 52 IP X4 B 0.48 3.95 1~230 2380 1040 60 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). - - - - - - - - - - - - - - - - - - - - - - -
min mixed-flow Inline plastic for round air ducts 315 50/60 320 49 IP X4 - 1 11.95 1~230 1890 1570 60 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). - - - - - - - - - - - - - - - - - - - - - - -
max mixed-flow Inline plastic for round air ducts 315 50/60 320 58 IP X4 - 1.42 11.95 1~230 2430 2050 60 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). - - - - - - - - - - - - - - - - - - - - - - -
- mixed-flow Inline plastic for round air ducts 125 50/60 25 29 IP X4 B - 2.15 1~230 1630 240 60 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). 0.11 - - - - - - - - - - - - - - - - - - - - - -
- mixed-flow Inline plastic for round air ducts 125 50/60 29 34 IP X4 B - 2.15 1~230 2300 350 60 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). 0.13 - - - - - - - - - - - - - - - - - - - - - -
max mixed-flow Inline plastic for round air ducts 160 50/60 50 46 IP X4 B 0.22 3.25 1~230 2620 565 60 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). - - - - - - - - - - - - - - - - - - - - - - -
min mixed-flow Inline plastic for round air ducts 160 50/60 42 37 IP X4 B 0.19 3.25 1~230 1940 415 60 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). - - - - - - - - - - - - - - - - - - - - - - -
min mixed-flow Inline plastic for round air ducts 100 60 23 27 IP X4 C - 1.75 1~230 2050 180 - To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). 0.10 - - - - - - - - - - - - - - - - - - - - - -
max mixed-flow Inline plastic for round air ducts 100 50/60 25 32 IP X4 C - 1.75 1~230 2620 245 - To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). 0.11 - - - - - - - - - - - - - - - - - - - - - -
- centrifugal flush mounting aluzinc for round air ducts 560 50 - 58 IP X4 - - 130.3 400 - 12750 - - - 1450 yes 3000 3 4 exhaust 3542 IP55 6.4 -25...+120 - - - - - - - - - - - -
- centrifugal flush mounting aluzinc for round air ducts 450 50 - 54 IP X4 - - 71.8 230 - 5920 - - - 1435 yes 750 1 4 exhaust 1644 IP55 5.6 -25...+120 - - - - - - - - - - - -
- centrifugal flush mounting aluzinc for round air ducts 315 50 - 58 IP X4 - - 41 400 - 4460 - - - 2885 yes 1100 3 2 exhaust 1239 IP55 2.4 -25...+120 - - - - - - - - - - - -
- centrifugal flush mounting aluzinc for round air ducts 315 50 - 57 IP X4 - - 40.2 230 - 4460 - - - 2810 yes 1100 1 2 exhaust 1239 IP55 7.6 -25...+120 - - - - - - - - - - - -
- centrifugal flush mounting aluzinc for round air ducts 315 50 - 50 IP X4 - - 37,2 400 - 1910 - - - 1385 yes 250 3 4 exhaust 531 IP55 0.7 -25...+120 - - - - - - - - - - - -
- centrifugal flush mounting aluzinc for round air ducts 315 50 - 48 IP X4 - - 37.2 230 - 1910 - - - 1320 yes 250 1 4 exhaust 531 IP55 2.16 -25...+120 - - - - - - - - - - - -
- centrifugal flush mounting aluzinc for round air ducts 355 50 - 58 IP X4 - - 48.1 400 - 3200 - - - 1375 yes 370 3 4 exhaust 889 IP55 1.1 -25...+120 - - - - - - - - - - - -
- centrifugal flush mounting aluzinc for round air ducts 355 50 - 57 IP X4 - - 47.4 230 - 3200 - - - 1452 yes 370 1 4 exhaust 889 IP55 3.3 -25...+120 - - - - - - - - - - - -
- centrifugal flush mounting aluzinc for round air ducts 400 50 - 53 IP X4 - - 58.1 400 - 4550 - - - 1400 yes 550 3 4 exhaust 1264 IP55 1.7 -25...+120 - - - - - - - - - - - -
- centrifugal flush mounting aluzinc for round air ducts 400 50 - 50 IP X4 - - 60.3 230 - 4550 - - - 1410 yes 550 1 4 exhaust 1264 IP55 4.4 -25...+120 - - - - - - - - - - - -
- centrifugal flush mounting aluzinc for round air ducts 450 50 - 56 IP X4 - - 73.3 400 - 5920 - - - 1435 yes 750 3 4 exhaust 1644 IP55 1.9 -25...+120 - - - - - - - - - - - -
- centrifugal flush mounting aluzinc for round air ducts 500 50 - 60 IP X4 - - 101.8 400 - 9100 - - - 1450 yes 1500 3 4 exhaust 2528 IP55 3.4 -25...+120 - - - - - - - - - - - -
- centrifugal flush mounting aluzinc for round air ducts 500 50 - 57 IP X4 - - 96.3 230 - 9100 - - - 1410 yes 1500 1 4 exhaust 2528 IP55 10.6 -25...+120 - - - - - - - - - - - -
- axial wall mounting , ceiling mounting - - - - - - - - - - - - - - - - - - - - - exhaust - - - - - 220 60 8 85 26 0.51 IP 44 Zone 1 - 0.5 100 2100
- axial wall mounting , ceiling mounting - - - - - - - - - 0.45 - - - - - - - - - - - exhaust - - - - - 220-240 50 8 - 27 - IP 44 Zone 1 95 0.05 100 -
- axial wall mounting , ceiling mounting - - - - - - - - - 0.45 - - - - - - - - - - - exhaust - - - - - 220 60 8 - 27 - IP 44 Zone 1 95 0.05 100 -
- axial wall mounting , ceiling mounting - - - - - - - - - - - - - - - - - - - - - exhaust - - - - - 220-240 50 8 85 26 0.51 IP 44 Zone 1 - 0.5 100 2100
- axial wall mounting , ceiling mounting - - 100 - - - - - - - - - - - - - 2154 - - - - - - - - - 0.05 220 60 8 95 27 0.45 IP 44 Zone 1 - - - -
- mixed-flow wall mounting - - - - - - - - - - - - - - - - - - - - - exhaust 25 - - - - 220-240 50 10 90 25 0.63 IP 24 - 0.056 100 2300