for round air ducts |
-
|
-
|
-
|
-
|
-
|
centrifugal |
Inline |
plastic |
yes |
315 |
4.9 |
50/60 |
- |
1~230 |
IP X4 |
48 |
1500 |
165 |
2500 |
1.15 |
-25 +60 |
To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). |
- |
-
|
for round air ducts |
-
|
-
|
-
|
-
|
-
|
centrifugal |
Inline |
plastic |
yes |
200 |
3 |
50/60 |
B |
1~230 |
IP X4 |
47 |
885 |
84 |
2700 |
0.64 |
-25 +60 |
To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). |
- |
-
|
for round air ducts |
-
|
-
|
-
|
-
|
-
|
centrifugal |
Inline |
plastic |
yes |
150 |
2.5 |
50/60 |
B |
1~230 |
IP X4 |
45 |
630 |
82 |
3400 |
0.63 |
-25 +60 |
To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). |
- |
600 |
for round air ducts |
electric reheating |
125 |
60 |
2.6 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
800 |
for round air ducts |
electric reheating |
125 |
80 |
3.5 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
1200 |
for round air ducts |
electric reheating |
125 |
90 |
5.2 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
800 |
for round air ducts |
electric reheating |
150 |
80 |
3.5 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
1200 |
for round air ducts |
electric reheating |
150 |
90 |
5.2 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
1700 |
for round air ducts |
electric reheating |
150 |
160 |
7.4 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
2000 |
for round air ducts |
electric reheating |
150 |
170 |
8.7 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
800 |
for round air ducts |
electric reheating |
160 |
80 |
3.5 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
1200 |
for round air ducts |
electric reheating |
160 |
150 |
5.2 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
1700 |
for round air ducts |
electric reheating |
160 |
160 |
7.4 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
2000 |
for round air ducts |
electric reheating |
160 |
170 |
8.7 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
1200 |
for round air ducts |
electric reheating |
200 |
150 |
5.2 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
1700 |
for round air ducts |
electric reheating |
200 |
160 |
7.4 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
2000 |
for round air ducts |
electric reheating |
200 |
170 |
8.7 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
1200 |
for round air ducts |
electric reheating |
250 |
180 |
5.2 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
2000 |
for round air ducts |
electric reheating |
250 |
200 |
8.7 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
3000 |
for round air ducts |
electric reheating |
250 |
375 |
13.0 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
-
|
for round air ducts |
-
|
-
|
-
|
-
|
-
|
mixed-flow |
Inline |
low-combustible polypropylene |
yes |
100 |
1.75 |
50 |
B |
1~230 |
IP X4 |
47 |
300 |
30 |
3680 |
0.29 |
-25...+55 |
To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). |
- |
-
|
for round air ducts |
-
|
-
|
-
|
-
|
-
|
mixed-flow |
Inline |
low-combustible polypropylene |
yes |
250 |
7.80 |
50 |
- |
1~230 |
IP X4 |
53 |
1285 |
169 |
2870 |
1.38 |
-25...+55 |
To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). |
- |
-
|
for round air ducts |
-
|
-
|
-
|
-
|
-
|
mixed-flow |
Inline |
low-combustible polypropylene |
yes |
125 |
2.15 |
50 |
B |
1~230 |
IP X4 |
49 |
450 |
40 |
3750 |
0.37 |
-25...+55 |
To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). |
- |
-
|
for round air ducts |
-
|
-
|
-
|
-
|
-
|
mixed-flow |
Inline |
low-combustible polypropylene |
yes |
200 |
3.95 |
50 |
- |
1~230 |
IP X4 |
49 |
1040 |
123 |
3390 |
1.02 |
-25...+55 |
To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). |
- |
-
|
for round air ducts |
-
|
-
|
-
|
-
|
-
|
mixed-flow |
Inline |
low-combustible polypropylene |
yes |
150 |
2.95 |
50 |
B |
1~230 |
IP X4 |
46 |
600 |
55 |
3390 |
0.48 |
-25...+55 |
To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). |