Mode FrequencyAir capacitySound pressure level at 3 mWeightIP CodeSpigot sizeEngine TypeVoltageCurrentPower consumptionMountingTypeDuct diameterDesignCasing materialDuctEC motorPhaseVoltageSound pressure level at 3 m distanceProtection ratingMax. transported air temperatureCurrentMaximum air capacity Frequency RPMPower consumptionRPMWeightSEC Class*SEC ClassSFPMaximum air capacityLamp powerSpeed
- - - - - - - - - - - Inline - 355 mixed-flow polymer coated steel for round air ducts yes 1 1~200-277 61 IP X4 -25 +40 2.5 4080 50/60 1700 460 - - - - - - - - -
- 50/60 82 35 0.44 IP 24 125 220V / 50-60Hz 220 0.048 5 wall mounting , ceiling mounting exhaust 125 axial - - - - - - - - - - - - - 2300 - - - - - - - -
- 50/60 78 34 0.49 IP 24 125 220V / 50-60Hz 220 0.049 5 wall mounting , ceiling mounting exhaust 125 axial - - - - - - - - - - - - - 2200 - - - - - - - -
- 50/60 80 35 0.5 IP 24 125 220V / 50-60Hz 220 0.048 5 wall mounting , ceiling mounting exhaust 125 axial - - - - - - - - - - - - - 2285 - - - - - - - -
max 50/60 90 25 0.55 IP 45 100 220V / 50-60Hz 230 0.052 7.5 wall mounting exhaust 100 axial - - - - - - - - - - - - - - - - - - - - - -
min 50/60 60 22 0.55 IP 45 100 220V / 50-60Hz 230 0.029 4 wall mounting exhaust 100 axial - - - - - - - - - - - - - - - - - - - - - -
max 50/60 170 32 0.78 IP 45 125 220V / 50-60Hz 230 0.09 13.5 wall mounting exhaust 125 axial - - - - - - - - - - - - - - - - - - - - - -
min 50/60 145 28 0.78 IP 45 125 220V / 50-60Hz 230 0.065 9.5 wall mounting exhaust 125 axial - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - Inline - 100 centrifugal plastic for round air ducts yes - 1~230 40 IP X4 -25 +60 0.62 340 50/60 3400 82 - 2 B To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). - - - - -
- - - - - - - - - - - Inline - 250 centrifugal plastic for round air ducts yes - 1~230 48 IP X4 -25 +60 1.10 1250 50/60 2600 165 - 4.3 - To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). - - - - -
- 60 85 25 0.51 IP 44 100 - 230 0.05 7.5 wall mounting , ceiling mounting exhaust - axial - - - - - - - - - - - - - 2000 - - - - - - - -
- - - - - - - - - - - Inline - 250 mixed-flow low-combustible polypropylene for round air ducts yes - 1~230 53 IP X4 -25...+55 1.38 1285 50 2870 169 - 7.80 - To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). - - - - -
- - - - - - - - - - - Inline - 125 mixed-flow low-combustible polypropylene for round air ducts yes - 1~230 49 IP X4 -25...+55 0.37 450 50 3750 40 - 2.15 B To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). - - - - -
- - - - - - - - - - - Inline - 200 mixed-flow low-combustible polypropylene for round air ducts yes - 1~230 49 IP X4 -25...+55 1.02 1040 50 3390 123 - 3.95 - To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). - - - - -
- - - - - - - - - - - Inline - 150 mixed-flow low-combustible polypropylene for round air ducts yes - 1~230 46 IP X4 -25...+55 0.48 600 50 3390 55 - 2.95 B To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). - - - - -
- - - - - - - - - - - Inline - 315 mixed-flow low-combustible polypropylene for round air ducts yes - 1~230 55 IP X4 -25...+55 1.25 1970 50 2826 284 - 11.95 - To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). - - - - -
- - - - - - - - - - - Inline - 160 mixed-flow low-combustible polypropylene for round air ducts yes - 1~230 46 IP X4 -25...+55 0.48 600 50 3390 55 - 3.25 B To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). - - - - -
max 50/60 100 26.5 0.55 IP 45 100 220V / 50-60Hz 230 0.137 3.6 wall mounting , ceiling mounting exhaust 100 axial - - - - - - - - - - - - - 2150 - - - - - - - -
min 50/60 70 22 0.55 IP 45 100 220V / 50-60Hz 230 0.063 1.7 wall mounting , ceiling mounting exhaust 100 axial - - - - - - - - - - - - - 1800 - - - - - - - -
- 50 85 27 0.51 IP 44 100 - 220-240 0.05 8 wall mounting , ceiling mounting exhaust - axial - - - - - - - - - - - - - 2000 - - - - - - - -
- 60 85 27 0.51 IP 44 100 - 220 0.05 8 wall mounting , ceiling mounting exhaust - axial - - - - - - - - - - - - - 2000 - - - - - - - -
- 50 155 32 0.75 IP 44 125 - 220-240 0.11 18 wall mounting , ceiling mounting exhaust - axial - - - - - - - - - - - - - 2200 - - - - - - - -
- 50 80 26 0.51 IP 44 100 - 12 1.06 9 wall mounting , ceiling mounting exhaust - axial - - - - - - - - - - - - - 1950 - - - - - - - -
- 60 155 32 0.75 IP 44 125 - 220 0.11 18 wall mounting , ceiling mounting exhaust - axial - - - - - - - - - - - - - 2200 - - - - - - - -
50 Hz, Speed 1 50 220 28 - IP X4 - - 220-240 0.15 31 - - - - - - - - - - - - - - - - - 936 - - - C 0.51 61 - 1
50 Hz, Speed 2 50 300 31 - IP X4 - - 220-240 0.22 49 - - - - - - - - - - - - - - - - - 1254 - - - C 0.59 83 - 2
60 Hz, Speed 1 60 200 27 - IP X4 - - 220-240 0.17 35 - - - - - - - - - - - - - - - - - 888 - - - C 0.63 56 - 1
60 Hz, Speed 2 60 320 32 - IP X4 - - 220-240 0.28 63 - - - - - - - - - - - - - - - - - 1320 - - - C 0.71 89 - 2
50 Hz, Speed 1 50 170 25 - IP X4 - - 220-240 0.12 23 - - - - - - - - - - - - - - - - - 756 - - - C 0.49 47 - 1
50 Hz, Speed 2 50 260 29 - IP X4 - - 220-240 0.18 39 - - - - - - - - - - - - - - - - - 1122 - - - C 0.54 72 - 2
60 Hz, Speed 1 60 160 25 - IP X4 - - 220-240 0.14 25 - - - - - - - - - - - - - - - - - 732 - - - C 0.56 44 - 1
60 Hz, Speed 2 60 270 30 - IP X4 - - 220-240 0.22 50 - - - - - - - - - - - - - - - - - 1140 - - - C 0.67 75 - 2
50 Hz, Speed 1 50 130 24 - IP X4 - - 220-240 0.1 20 - - - - - - - - - - - - - - - - - 714 - - - D 0.55 36 - 1
50 Hz, Speed 2 50 210 27 - IP X4 - - 220-240 0.13 29 - - - - - - - - - - - - - - - - - 1026 - - - D 0.5 58 - 2
60 Hz, Speed 1 60 130 24 - IP X4 - - 220-240 0.11 21 - - - - - - - - - - - - - - - - - 588 - - - D 0.58 36 - 1
60 Hz, Speed 2 60 225 28 - IP X4 - - 220-240 0.15 34 - - - - - - - - - - - - - - - - - 936 - - - D 0.54 63 - 2
- 50/60 187 23...25 - IP X4 - - 120-240 0.18 (0.3) 19 - - - - - - - - - - - - - - - - - 1100 - - - C 0.37 52 2 х 10 -