50 Hz |
|
centrifugal |
ceiling mounting |
galvanized steel , ABS plastic |
for round air ducts |
125 |
3.4 |
43 |
225 |
IP X4 |
C |
56 |
1~230 |
yes |
yes |
50 |
2300 |
0.34 |
-25 +45 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
60 Hz |
|
centrifugal |
ceiling mounting |
galvanized steel , ABS plastic |
for round air ducts |
125 |
3.4 |
44 |
240 |
IP X4 |
C |
58 |
1~230 |
yes |
yes |
60 |
2570 |
0.35 |
-25 +45 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
50 Hz |
|
centrifugal |
ceiling mounting |
galvanized steel , ABS plastic |
for round air ducts |
125 |
3.4 |
48 |
310 |
IP X4 |
C |
61 |
1~230 |
no |
yes |
50 |
2500 |
0.26 |
-25 +50 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
60 Hz |
|
centrifugal |
ceiling mounting |
galvanized steel , ABS plastic |
for round air ducts |
125 |
3.4 |
49 |
320 |
IP X4 |
C |
81 |
1~230 |
no |
yes |
60 |
2740 |
0.36 |
-25 +50 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
supply and exhaust |
centrifugal |
outdoor mounting , Inline |
polymer coated steel |
for round air ducts |
250 |
5.1 |
44 |
-
|
IP X4 |
B |
100 |
230 |
-
|
-
|
50/60 |
2500 |
0.74 |
-25 +60 |
yes |
yes |
yes |
no |
1 |
985 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
supply and exhaust |
centrifugal |
outdoor mounting , Inline |
polymer coated steel |
for round air ducts |
160 |
4.9 |
48 |
-
|
IP X4 |
B |
108 |
230 |
-
|
-
|
50/60 |
3030 |
0.90 |
-25 +60 |
yes |
yes |
no |
no |
1 |
785 |
To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
supply and exhaust |
centrifugal |
outdoor mounting , Inline |
polymer coated steel |
for round air ducts |
200 |
5.4 |
48 |
-
|
IP X4 |
B |
100 |
230 |
-
|
-
|
50/60 |
2400 |
0.74 |
-25 +60 |
yes |
yes |
no |
yes |
1 |
1010 |
To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
supply and exhaust |
centrifugal |
outdoor mounting , Inline |
polymer coated steel |
for round air ducts |
100 |
3.2 |
44 |
-
|
IP X4 |
B |
90 |
230 |
-
|
-
|
50/60 |
3600 |
0.70 |
-25 +60 |
yes |
yes |
no |
no |
1 |
345 |
To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
supply and exhaust |
centrifugal |
outdoor mounting , Inline |
polymer coated steel |
for round air ducts |
200 |
5.1 |
47 |
-
|
IP X4 |
B |
83 |
230 |
-
|
-
|
50/60 |
2500 |
0.63 |
-25 +60 |
yes |
yes |
no |
no |
1 |
845 |
To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
supply and exhaust |
centrifugal |
outdoor mounting , Inline |
polymer coated steel |
for round air ducts |
250 |
5.1 |
46 |
-
|
IP X4 |
- |
164 |
230 |
-
|
-
|
50/60 |
2900 |
1.15 |
-25 +60 |
yes |
yes |
no |
no |
1 |
1230 |
To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
supply and exhaust |
centrifugal |
outdoor mounting , Inline |
polymer coated steel |
for round air ducts |
125 |
3.2 |
45 |
-
|
IP X4 |
B |
83 |
230 |
-
|
-
|
50/60 |
3400 |
0.58 |
-25 +60 |
yes |
yes |
no |
no |
1 |
480 |
To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
supply and exhaust |
centrifugal |
outdoor mounting , Inline |
polymer coated steel |
for round air ducts |
315 |
7.3 |
48 |
-
|
IP X4 |
- |
164 |
230 |
-
|
-
|
50/60 |
2900 |
1.15 |
-25 +60 |
yes |
yes |
no |
no |
1 |
1370 |
To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
supply and exhaust |
centrifugal |
outdoor mounting , Inline |
polymer coated steel |
for round air ducts |
150 |
4.9 |
48 |
-
|
IP X4 |
B |
107 |
230 |
-
|
-
|
50/60 |
3060 |
0.89 |
-25 +60 |
yes |
yes |
no |
no |
1 |
700 |
To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
supply and exhaust |
centrifugal |
outdoor mounting , Inline |
polymer coated steel |
for round air ducts |
355 |
15.8 |
62 |
-
|
IP X4 |
- |
693 |
230 |
-
|
-
|
50/60 |
2768 |
3.07 |
-25 +60 |
yes |
yes |
no |
no |
1 |
3450 |
To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
supply and exhaust |
centrifugal |
outdoor mounting , Inline |
polymer coated steel |
for round air ducts |
400 |
18.7 |
67 |
-
|
IP X4 |
- |
704 |
230 |
-
|
-
|
50/60 |
2206 |
3.13 |
-25 +60 |
yes |
yes |
no |
no |
1 |
4790 |
To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
supply and exhaust |
centrifugal |
outdoor mounting , Inline |
polymer coated steel |
for round air ducts |
315 |
9.4 |
49 |
-
|
IP X4 |
- |
183 |
230 |
-
|
-
|
50/60 |
2780 |
1.44 |
-25 +60 |
yes |
yes |
yes |
no |
1 |
1820 |
To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
exhaust |
axial |
wall mounting , ceiling mounting |
-
|
-
|
100 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
14 |
0.085 |
0.86 |
100 |
220-240 |
IP 34 |
220-240V / 50-60Hz |
50/60 |
33 |
88 |
2300 |
- |
exhaust |
axial |
wall mounting , ceiling mounting |
-
|
-
|
125 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
16 |
0.1 |
1.11 |
125 |
220-240 |
IP 34 |
220-240V / 50-60Hz |
50/60 |
34 |
167 |
2400 |
- |
exhaust |
axial |
wall mounting , ceiling mounting |
-
|
-
|
150 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
24 |
0.13 |
1.35 |
150 |
220-240 |
IP 34 |
220-240V / 50Hz or 220-240V / 60Hz |
50; 60 |
37 |
265 |
2400 |
- |
exhaust |
axial |
wall mounting , ceiling mounting |
-
|
-
|
100 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
16 |
0.1 |
0.94 |
100 |
220-240 |
IP 34 |
220-240V / 50-60Hz |
50/60 |
36 |
115 |
2300 |
- |
exhaust |
axial |
wall mounting , ceiling mounting |
-
|
-
|
125 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
24 |
0.105 |
1.18 |
125 |
220-240 |
IP 34 |
220-240V / 50-60Hz |
50/60 |
36 |
209 |
2400 |
- |
exhaust |
axial |
wall mounting , ceiling mounting |
-
|
-
|
150 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
30 |
0.13 |
1.49 |
150 |
220-240 |
IP 34 |
220-240V / 50Hz or 220-240V / 60Hz |
50; 60 |
39 |
310 |
2400 |
- |
exhaust |
axial |
wall mounting , ceiling mounting |
-
|
-
|
100 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
14 |
1.5 |
0.88 |
100 |
12 |
IP 34 |
12V / 50-60Hz |
50/60 |
32 |
77 |
2200 |
- |
exhaust |
axial |
wall mounting , ceiling mounting |
-
|
-
|
125 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
16 |
1.7 |
1.06 |
125 |
12 |
IP 34 |
12V / 50-60Hz |
50/60 |
33 |
149 |
2300 |
- |
exhaust |
axial |
wall mounting , ceiling mounting |
-
|
-
|
150 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
29 |
2 |
1.31 |
150 |
12 |
IP 34 |
12V / 50Hz or 12V / 60Hz |
50; 60 |
36 |
236 |
2300 |
- |
exhaust |
axial |
wall mounting , ceiling mounting |
-
|
-
|
100 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
18 |
1.5 |
0.72 |
100 |
12 |
IP 24 |
12V / 50-60Hz |
50/60 |
33 |
86 |
2200 |
- |
exhaust |
axial |
wall mounting , ceiling mounting |
-
|
-
|
100 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
20 |
0.1 |
0.73 |
100 |
220-240 |
IP 24 |
220-240V / 50-60Hz |
50/60 |
37 |
99 |
2300 |