outdoor mounting , Inline |
centrifugal |
supply and exhaust |
150 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
230 |
107 |
50/60 |
B |
48 |
IP X4 |
3060 |
4.9 |
0.89 |
-25 +60 |
for round air ducts |
polymer coated steel |
yes |
yes |
no |
no |
1 |
700 |
To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). |
- |
outdoor mounting , Inline |
centrifugal |
supply and exhaust |
355 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
230 |
693 |
50/60 |
- |
62 |
IP X4 |
2768 |
15.8 |
3.07 |
-25 +60 |
for round air ducts |
polymer coated steel |
yes |
yes |
no |
no |
1 |
3450 |
To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). |
- |
outdoor mounting , Inline |
centrifugal |
supply and exhaust |
400 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
230 |
704 |
50/60 |
- |
67 |
IP X4 |
2206 |
18.7 |
3.13 |
-25 +60 |
for round air ducts |
polymer coated steel |
yes |
yes |
no |
no |
1 |
4790 |
To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). |
- |
outdoor mounting , Inline |
centrifugal |
supply and exhaust |
315 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
230 |
183 |
50/60 |
- |
49 |
IP X4 |
2780 |
9.4 |
1.44 |
-25 +60 |
for round air ducts |
polymer coated steel |
yes |
yes |
yes |
no |
1 |
1820 |
To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). |
- |
wall mounting , ceiling mounting |
axial |
exhaust |
100 |
14 |
0.085 |
0.86 |
100 |
220-240 |
IP 34 |
220-240V / 50-60Hz |
50/60 |
33 |
88 |
2300 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
wall mounting , ceiling mounting |
axial |
exhaust |
125 |
16 |
0.1 |
1.11 |
125 |
220-240 |
IP 34 |
220-240V / 50-60Hz |
50/60 |
34 |
167 |
2400 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
wall mounting , ceiling mounting |
axial |
exhaust |
150 |
24 |
0.13 |
1.35 |
150 |
220-240 |
IP 34 |
220-240V / 50Hz or 220-240V / 60Hz |
50; 60 |
37 |
265 |
2400 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
wall mounting , ceiling mounting |
axial |
exhaust |
100 |
16 |
0.1 |
0.94 |
100 |
220-240 |
IP 34 |
220-240V / 50-60Hz |
50/60 |
36 |
115 |
2300 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
wall mounting , ceiling mounting |
axial |
exhaust |
125 |
24 |
0.105 |
1.18 |
125 |
220-240 |
IP 34 |
220-240V / 50-60Hz |
50/60 |
36 |
209 |
2400 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
wall mounting , ceiling mounting |
axial |
exhaust |
150 |
30 |
0.13 |
1.49 |
150 |
220-240 |
IP 34 |
220-240V / 50Hz or 220-240V / 60Hz |
50; 60 |
39 |
310 |
2400 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
wall mounting , ceiling mounting |
axial |
exhaust |
100 |
14 |
1.5 |
0.88 |
100 |
12 |
IP 34 |
12V / 50-60Hz |
50/60 |
32 |
77 |
2200 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
wall mounting , ceiling mounting |
axial |
exhaust |
125 |
16 |
1.7 |
1.06 |
125 |
12 |
IP 34 |
12V / 50-60Hz |
50/60 |
33 |
149 |
2300 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
wall mounting , ceiling mounting |
axial |
exhaust |
150 |
29 |
2 |
1.31 |
150 |
12 |
IP 34 |
12V / 50Hz or 12V / 60Hz |
50; 60 |
36 |
236 |
2300 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
wall mounting , ceiling mounting |
axial |
exhaust |
100 |
18 |
1.5 |
0.72 |
100 |
12 |
IP 24 |
12V / 50-60Hz |
50/60 |
33 |
86 |
2200 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
wall mounting , ceiling mounting |
axial |
exhaust |
100 |
20 |
0.1 |
0.73 |
100 |
220-240 |
IP 24 |
220-240V / 50-60Hz |
50/60 |
37 |
99 |
2300 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
wall mounting , ceiling mounting |
axial |
exhaust |
100 |
20 |
0.1 |
0.79 |
100 |
220-240 |
IP 24 |
220-240V / 50-60Hz |
50/60 |
37 |
128 |
2300 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
wall mounting , ceiling mounting |
axial |
exhaust |
100 |
18 |
0.085 |
0.73 |
100 |
220-240 |
IP 24 |
220-240V / 50-60Hz |
50/60 |
34 |
98 |
2300 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
wall mounting , ceiling mounting |
axial |
exhaust |
125 |
22 |
0.1 |
0.83 |
125 |
220-240 |
IP 24 |
220-240V / 50-60Hz |
50/60 |
35 |
185 |
2400 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
wall mounting , ceiling mounting |
axial |
exhaust |
150 |
29 |
2 |
1.13 |
150 |
12 |
IP 24 |
12V / 50Hz or 12V / 60Hz |
50; 60 |
38 |
263 |
2300 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
wall mounting , ceiling mounting |
axial |
exhaust |
150 |
32 |
0.14 |
1.14 |
150 |
220-240 |
IP 24 |
220-240V / 50Hz or 220-240V / 60Hz |
50; 60 |
41 |
307 |
2400 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
wall mounting , ceiling mounting |
axial |
exhaust |
150 |
32 |
0.13 |
1.2 |
150 |
220-240 |
IP 24 |
220-240V / 50Hz or 220-240V / 60Hz |
50; 60 |
41 |
345 |
2400 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
wall mounting , ceiling mounting |
axial |
exhaust |
150 |
26 |
0.13 |
1.14 |
150 |
220-240 |
IP 24 |
220-240V / 50Hz or 220-240V / 60Hz |
50; 60 |
39 |
295 |
2400 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
wall mounting , ceiling mounting |
axial |
exhaust |
125 |
22 |
1.7 |
0.82 |
125 |
12 |
IP 24 |
12V / 50-60Hz |
50/60 |
34 |
165 |
2300 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
wall mounting , ceiling mounting |
axial |
exhaust |
125 |
29 |
0.13 |
0.83 |
125 |
220-240 |
IP 24 |
220-240V / 50-60Hz |
50/60 |
39 |
188 |
2400 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
wall mounting , ceiling mounting |
axial |
exhaust |
125 |
29 |
0.13 |
0.89 |
125 |
220-240 |
IP 24 |
220-240V / 50-60Hz |
50/60 |
37 |
232 |
2400 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|