outdoor mounting , Inline |
centrifugal |
supply and exhaust |
125 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
polymer coated steel |
for round air ducts |
3.2 |
83 |
-
|
45 |
IP X4 |
B |
230 |
-25 +60 |
0.58 |
3400 |
50/60 |
-
|
-
|
yes |
yes |
no |
no |
1 |
480 |
To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). |
max |
wall mounting , ceiling mounting |
axial |
supply and exhaust |
150 |
2030 |
32 |
150 |
50/60 |
187 |
220-240V / 50-60Hz |
IP 24 |
220-240 |
0.045 |
1.02 |
supply |
7.6 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
min |
wall mounting , ceiling mounting |
axial |
supply and exhaust |
150 |
1210 |
26 |
150 |
50/60 |
110 |
220-240V / 50-60Hz |
IP 24 |
220-240 |
0.025 |
1.02 |
supply |
5.1 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
50 Hz |
ceiling mounting |
centrifugal |
|
100 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
galvanized steel , ABS plastic |
for round air ducts |
3.4 |
56 |
190 |
42 |
IP X4 |
C |
1~230 |
-25 +45 |
0.34 |
2300 |
50 |
yes |
yes |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
60 Hz |
ceiling mounting |
centrifugal |
|
100 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
galvanized steel , ABS plastic |
for round air ducts |
3.4 |
58 |
205 |
43 |
IP X4 |
C |
1~230 |
-25 +45 |
0.35 |
2570 |
60 |
yes |
yes |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
50 Hz |
ceiling mounting |
centrifugal |
|
150 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
galvanized steel , ABS plastic |
for round air ducts |
6.5 |
112 |
485 |
52 |
IP X4 |
C |
1~230 |
-25 +50 |
0.5 |
2465 |
50 |
yes |
no |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
60 Hz |
ceiling mounting |
centrifugal |
|
150 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
galvanized steel , ABS plastic |
for round air ducts |
6.5 |
136 |
531 |
53 |
IP X4 |
C |
1~230 |
-25 +50 |
0.6 |
2550 |
60 |
yes |
no |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
50 Hz |
ceiling mounting |
centrifugal |
|
100 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
galvanized steel , ABS plastic |
for round air ducts |
3.4 |
61 |
240 |
47 |
IP X4 |
C |
1~230 |
-25 +50 |
0.26 |
2500 |
50 |
yes |
no |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
60 Hz |
ceiling mounting |
centrifugal |
|
100 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
galvanized steel , ABS plastic |
for round air ducts |
3.4 |
79 |
250 |
48 |
IP X4 |
C |
1~230 |
-25 +50 |
0.35 |
2730 |
60 |
yes |
no |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
50 Hz |
ceiling mounting |
centrifugal |
|
125 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
galvanized steel , ABS plastic |
for round air ducts |
3.4 |
56 |
225 |
43 |
IP X4 |
C |
1~230 |
-25 +45 |
0.34 |
2300 |
50 |
yes |
yes |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
60 Hz |
ceiling mounting |
centrifugal |
|
125 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
galvanized steel , ABS plastic |
for round air ducts |
3.4 |
58 |
240 |
44 |
IP X4 |
C |
1~230 |
-25 +45 |
0.35 |
2570 |
60 |
yes |
yes |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
50 Hz |
ceiling mounting |
centrifugal |
|
125 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
galvanized steel , ABS plastic |
for round air ducts |
3.4 |
61 |
310 |
48 |
IP X4 |
C |
1~230 |
-25 +50 |
0.26 |
2500 |
50 |
yes |
no |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
60 Hz |
ceiling mounting |
centrifugal |
|
125 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
galvanized steel , ABS plastic |
for round air ducts |
3.4 |
81 |
320 |
49 |
IP X4 |
C |
1~230 |
-25 +50 |
0.36 |
2740 |
60 |
yes |
no |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
outdoor mounting , Inline |
centrifugal |
supply and exhaust |
250 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
polymer coated steel |
for round air ducts |
5.1 |
100 |
-
|
44 |
IP X4 |
B |
230 |
-25 +60 |
0.74 |
2500 |
50/60 |
-
|
-
|
yes |
yes |
yes |
no |
1 |
985 |
-
|
- |
outdoor mounting , Inline |
centrifugal |
supply and exhaust |
160 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
polymer coated steel |
for round air ducts |
4.9 |
108 |
-
|
48 |
IP X4 |
B |
230 |
-25 +60 |
0.90 |
3030 |
50/60 |
-
|
-
|
yes |
yes |
no |
no |
1 |
785 |
To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). |
- |
outdoor mounting , Inline |
centrifugal |
supply and exhaust |
200 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
polymer coated steel |
for round air ducts |
5.4 |
100 |
-
|
48 |
IP X4 |
B |
230 |
-25 +60 |
0.74 |
2400 |
50/60 |
-
|
-
|
yes |
yes |
no |
yes |
1 |
1010 |
To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). |
- |
outdoor mounting , Inline |
centrifugal |
supply and exhaust |
100 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
polymer coated steel |
for round air ducts |
3.2 |
90 |
-
|
44 |
IP X4 |
B |
230 |
-25 +60 |
0.70 |
3600 |
50/60 |
-
|
-
|
yes |
yes |
no |
no |
1 |
345 |
To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). |
- |
outdoor mounting , Inline |
centrifugal |
supply and exhaust |
200 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
polymer coated steel |
for round air ducts |
5.1 |
83 |
-
|
47 |
IP X4 |
B |
230 |
-25 +60 |
0.63 |
2500 |
50/60 |
-
|
-
|
yes |
yes |
no |
no |
1 |
845 |
To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). |
- |
outdoor mounting , Inline |
centrifugal |
supply and exhaust |
250 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
polymer coated steel |
for round air ducts |
5.1 |
164 |
-
|
46 |
IP X4 |
- |
230 |
-25 +60 |
1.15 |
2900 |
50/60 |
-
|
-
|
yes |
yes |
no |
no |
1 |
1230 |
To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). |
- |
wall mounting , ceiling mounting |
axial |
exhaust |
100 |
2300 |
33 |
100 |
50/60 |
88 |
220-240V / 50-60Hz |
IP 34 |
220-240 |
0.085 |
0.86 |
-
|
14 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
wall mounting , ceiling mounting |
axial |
exhaust |
150 |
2400 |
39 |
150 |
50; 60 |
310 |
220-240V / 50Hz or 220-240V / 60Hz |
IP 34 |
220-240 |
0.13 |
1.49 |
-
|
30 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
wall mounting , ceiling mounting |
axial |
exhaust |
125 |
2400 |
36 |
125 |
50/60 |
209 |
220-240V / 50-60Hz |
IP 34 |
220-240 |
0.105 |
1.18 |
-
|
24 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
wall mounting , ceiling mounting |
axial |
exhaust |
100 |
2300 |
36 |
100 |
50/60 |
115 |
220-240V / 50-60Hz |
IP 34 |
220-240 |
0.1 |
0.94 |
-
|
16 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
wall mounting , ceiling mounting |
axial |
exhaust |
150 |
2400 |
37 |
150 |
50; 60 |
265 |
220-240V / 50Hz or 220-240V / 60Hz |
IP 34 |
220-240 |
0.13 |
1.35 |
-
|
24 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
wall mounting , ceiling mounting |
axial |
exhaust |
125 |
2400 |
34 |
125 |
50/60 |
167 |
220-240V / 50-60Hz |
IP 34 |
220-240 |
0.1 |
1.11 |
-
|
16 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
outdoor mounting , Inline |
centrifugal |
supply and exhaust |
355 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
polymer coated steel |
for round air ducts |
15.8 |
693 |
-
|
62 |
IP X4 |
- |
230 |
-25 +60 |
3.07 |
2768 |
50/60 |
-
|
-
|
yes |
yes |
no |
no |
1 |
3450 |
To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). |
- |
outdoor mounting , Inline |
centrifugal |
supply and exhaust |
315 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
polymer coated steel |
for round air ducts |
7.3 |
164 |
-
|
48 |
IP X4 |
- |
230 |
-25 +60 |
1.15 |
2900 |
50/60 |
-
|
-
|
yes |
yes |
no |
no |
1 |
1370 |
To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). |
- |
outdoor mounting , Inline |
centrifugal |
supply and exhaust |
150 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
polymer coated steel |
for round air ducts |
4.9 |
107 |
-
|
48 |
IP X4 |
B |
230 |
-25 +60 |
0.89 |
3060 |
50/60 |
-
|
-
|
yes |
yes |
no |
no |
1 |
700 |
To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). |
max |
wall mounting , ceiling mounting |
axial |
supply and exhaust |
150 |
1950 |
33 |
150 |
50/60 |
202 |
220-240V / 50-60Hz |
IP 24 |
220-240 |
0.045 |
1.02 |
exhaust |
8.7 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
min |
wall mounting , ceiling mounting |
axial |
supply and exhaust |
150 |
1215 |
28 |
150 |
50/60 |
123 |
220-240V / 50-60Hz |
IP 24 |
220-240 |
0.025 |
1.02 |
exhaust |
5.2 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
- |
outdoor mounting , Inline |
centrifugal |
supply and exhaust |
400 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
polymer coated steel |
for round air ducts |
18.7 |
704 |
-
|
67 |
IP X4 |
- |
230 |
-25 +60 |
3.13 |
2206 |
50/60 |
-
|
-
|
yes |
yes |
no |
no |
1 |
4790 |
To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). |
- |
outdoor mounting , Inline |
centrifugal |
supply and exhaust |
315 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
polymer coated steel |
for round air ducts |
9.4 |
183 |
-
|
49 |
IP X4 |
- |
230 |
-25 +60 |
1.44 |
2780 |
50/60 |
-
|
-
|
yes |
yes |
yes |
no |
1 |
1820 |
To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). |