Selected products
Mode MountingDesignTypeDuct diameterRPMSound pressure level at 3 mSpigot sizeFrequencyAir capacityEngine TypeIP CodeVoltageCurrentWeightModePower consumptionCasing materialDuctWeightPower consumptionMaximum air capacity Sound pressure level at 3 m distanceProtection ratingSEC ClassVoltageMax. transported air temperatureCurrentRPMFrequency Backdraft damperLow-powered motorOutdoor mountingEC motorLow-powered motorHigh-power versionPhaseAir capacity*
- outdoor mounting , Inline centrifugal supply and exhaust 125 - - - - - - - - - - - - polymer coated steel for round air ducts 3.2 83 - 45 IP X4 B 230 -25 +60 0.58 3400 50/60 - - yes yes no no 1 480 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor).
max wall mounting , ceiling mounting axial supply and exhaust 150 2030 32 150 50/60 187 220-240V / 50-60Hz IP 24 220-240 0.045 1.02 supply 7.6 - - - - - - - - - - - - - - - - - - - - - -
min wall mounting , ceiling mounting axial supply and exhaust 150 1210 26 150 50/60 110 220-240V / 50-60Hz IP 24 220-240 0.025 1.02 supply 5.1 - - - - - - - - - - - - - - - - - - - - - -
50 Hz ceiling mounting centrifugal 100 - - - - - - - - - - - - galvanized steel , ABS plastic for round air ducts 3.4 56 190 42 IP X4 C 1~230 -25 +45 0.34 2300 50 yes yes - - - - - - -
60 Hz ceiling mounting centrifugal 100 - - - - - - - - - - - - galvanized steel , ABS plastic for round air ducts 3.4 58 205 43 IP X4 C 1~230 -25 +45 0.35 2570 60 yes yes - - - - - - -
50 Hz ceiling mounting centrifugal 150 - - - - - - - - - - - - galvanized steel , ABS plastic for round air ducts 6.5 112 485 52 IP X4 C 1~230 -25 +50 0.5 2465 50 yes no - - - - - - -
60 Hz ceiling mounting centrifugal 150 - - - - - - - - - - - - galvanized steel , ABS plastic for round air ducts 6.5 136 531 53 IP X4 C 1~230 -25 +50 0.6 2550 60 yes no - - - - - - -
50 Hz ceiling mounting centrifugal 100 - - - - - - - - - - - - galvanized steel , ABS plastic for round air ducts 3.4 61 240 47 IP X4 C 1~230 -25 +50 0.26 2500 50 yes no - - - - - - -
60 Hz ceiling mounting centrifugal 100 - - - - - - - - - - - - galvanized steel , ABS plastic for round air ducts 3.4 79 250 48 IP X4 C 1~230 -25 +50 0.35 2730 60 yes no - - - - - - -
50 Hz ceiling mounting centrifugal 125 - - - - - - - - - - - - galvanized steel , ABS plastic for round air ducts 3.4 56 225 43 IP X4 C 1~230 -25 +45 0.34 2300 50 yes yes - - - - - - -
60 Hz ceiling mounting centrifugal 125 - - - - - - - - - - - - galvanized steel , ABS plastic for round air ducts 3.4 58 240 44 IP X4 C 1~230 -25 +45 0.35 2570 60 yes yes - - - - - - -
50 Hz ceiling mounting centrifugal 125 - - - - - - - - - - - - galvanized steel , ABS plastic for round air ducts 3.4 61 310 48 IP X4 C 1~230 -25 +50 0.26 2500 50 yes no - - - - - - -
60 Hz ceiling mounting centrifugal 125 - - - - - - - - - - - - galvanized steel , ABS plastic for round air ducts 3.4 81 320 49 IP X4 C 1~230 -25 +50 0.36 2740 60 yes no - - - - - - -
- outdoor mounting , Inline centrifugal supply and exhaust 250 - - - - - - - - - - - - polymer coated steel for round air ducts 5.1 100 - 44 IP X4 B 230 -25 +60 0.74 2500 50/60 - - yes yes yes no 1 985 -
- outdoor mounting , Inline centrifugal supply and exhaust 160 - - - - - - - - - - - - polymer coated steel for round air ducts 4.9 108 - 48 IP X4 B 230 -25 +60 0.90 3030 50/60 - - yes yes no no 1 785 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor).
- outdoor mounting , Inline centrifugal supply and exhaust 200 - - - - - - - - - - - - polymer coated steel for round air ducts 5.4 100 - 48 IP X4 B 230 -25 +60 0.74 2400 50/60 - - yes yes no yes 1 1010 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor).
- outdoor mounting , Inline centrifugal supply and exhaust 100 - - - - - - - - - - - - polymer coated steel for round air ducts 3.2 90 - 44 IP X4 B 230 -25 +60 0.70 3600 50/60 - - yes yes no no 1 345 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor).
- outdoor mounting , Inline centrifugal supply and exhaust 200 - - - - - - - - - - - - polymer coated steel for round air ducts 5.1 83 - 47 IP X4 B 230 -25 +60 0.63 2500 50/60 - - yes yes no no 1 845 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor).
- outdoor mounting , Inline centrifugal supply and exhaust 250 - - - - - - - - - - - - polymer coated steel for round air ducts 5.1 164 - 46 IP X4 - 230 -25 +60 1.15 2900 50/60 - - yes yes no no 1 1230 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor).
- wall mounting , ceiling mounting axial exhaust 100 2300 33 100 50/60 88 220-240V / 50-60Hz IP 34 220-240 0.085 0.86 - 14 - - - - - - - - - - - - - - - - - - - - - -
- wall mounting , ceiling mounting axial exhaust 150 2400 39 150 50; 60 310 220-240V / 50Hz or 220-240V / 60Hz IP 34 220-240 0.13 1.49 - 30 - - - - - - - - - - - - - - - - - - - - - -
- wall mounting , ceiling mounting axial exhaust 125 2400 36 125 50/60 209 220-240V / 50-60Hz IP 34 220-240 0.105 1.18 - 24 - - - - - - - - - - - - - - - - - - - - - -
- wall mounting , ceiling mounting axial exhaust 100 2300 36 100 50/60 115 220-240V / 50-60Hz IP 34 220-240 0.1 0.94 - 16 - - - - - - - - - - - - - - - - - - - - - -
- wall mounting , ceiling mounting axial exhaust 150 2400 37 150 50; 60 265 220-240V / 50Hz or 220-240V / 60Hz IP 34 220-240 0.13 1.35 - 24 - - - - - - - - - - - - - - - - - - - - - -
- wall mounting , ceiling mounting axial exhaust 125 2400 34 125 50/60 167 220-240V / 50-60Hz IP 34 220-240 0.1 1.11 - 16 - - - - - - - - - - - - - - - - - - - - - -
- outdoor mounting , Inline centrifugal supply and exhaust 355 - - - - - - - - - - - - polymer coated steel for round air ducts 15.8 693 - 62 IP X4 - 230 -25 +60 3.07 2768 50/60 - - yes yes no no 1 3450 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor).
- outdoor mounting , Inline centrifugal supply and exhaust 315 - - - - - - - - - - - - polymer coated steel for round air ducts 7.3 164 - 48 IP X4 - 230 -25 +60 1.15 2900 50/60 - - yes yes no no 1 1370 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor).
- outdoor mounting , Inline centrifugal supply and exhaust 150 - - - - - - - - - - - - polymer coated steel for round air ducts 4.9 107 - 48 IP X4 B 230 -25 +60 0.89 3060 50/60 - - yes yes no no 1 700 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor).
max wall mounting , ceiling mounting axial supply and exhaust 150 1950 33 150 50/60 202 220-240V / 50-60Hz IP 24 220-240 0.045 1.02 exhaust 8.7 - - - - - - - - - - - - - - - - - - - - - -
min wall mounting , ceiling mounting axial supply and exhaust 150 1215 28 150 50/60 123 220-240V / 50-60Hz IP 24 220-240 0.025 1.02 exhaust 5.2 - - - - - - - - - - - - - - - - - - - - - -
- outdoor mounting , Inline centrifugal supply and exhaust 400 - - - - - - - - - - - - polymer coated steel for round air ducts 18.7 704 - 67 IP X4 - 230 -25 +60 3.13 2206 50/60 - - yes yes no no 1 4790 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor).
- outdoor mounting , Inline centrifugal supply and exhaust 315 - - - - - - - - - - - - polymer coated steel for round air ducts 9.4 183 - 49 IP X4 - 230 -25 +60 1.44 2780 50/60 - - yes yes yes no 1 1820 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor).
Share your opinion

Questionnaire
Is our site helpful for your business development?