Mode DesignMountingCasing materialDuctDuct diameterPower consumptionMaximum air capacity Protection ratingSound pressure level at 3 m distanceSEC ClassVoltageWeightCurrentFrequency Max. transported air temperatureRPM*CurrentRPMMaximum air capacityPowerCurrent Motor protection ratingFrequencyPhaseSEC ClassWeightConnected air duct sizeFilter: supplyFilter: extractRPMVoltageHeatingSound pressure level at 3 m distanceInsulationHeat recovery efficiencyHeat exchanger typeHeat exchanger materialTransported air temperatureAir capacityMaximum unit power without an electric heaterElectric heater powerMaximum unit power with an electric heaterMax. unit current without electric heaterMax. unit current with electric heaterElectric heater currentNumber of water (glycol) coil rowsMaximum unit currentMaximum unit power
- - - aluzinc - - - - - - - - - - - - - option - - - - - - 50/60 1 A 44 160 G4 (F7*) G4 3270 230 electric heating 27 20 mm mineral wool 69-87 counter-flow enthalpy -25 ... +40 340 180 1500 1680 1.4 7.9 6.5 - - -
- - - aluzinc - - - - - - - - - - - - - option - - - - - - 50/60 1 A 67 200 G4 (F7*) G4 3100 230 electric heating 30 20 mm mineral wool 69-87 counter-flow enthalpy -25 ... +40 620 297 2000 2297 2.4 11.1 8.7 - - -
- - - aluzinc - - - - - - - - - - - - - option - - - - - - 50/60 1 A 68 200 G4 (F7*) G4 3100 230 water heating 30 20 mm mineral wool 69-87 counter-flow enthalpy -25 ... +40 620 - - - - - - 2 2.4 297
- - - aluzinc - - - - - - - - - - - - - option - - - - - - 50/60 1 A 111 250 G4 (F7*) G4 2720 230 electric heating 33 20 mm mineral wool 69-85 counter-flow enthalpy -25 ... +40 1030 442 3300 3742 3.1 17.4 14.3 - - -
- - - aluzinc - - - - - - - - - - - - - option - - - - - - 50/60 1 A 112 250 G4 (F7*) G4 2720 230 water heating 33 20 mm mineral wool 69-85 counter-flow enthalpy -25 ... +40 1030 - - - - - - 2 3 442
- - - aluzinc - - - - - - - - - - - - - option - - - - - - 50/60 3 NRVU 140 315 G4 G4 2920 400 electric heating 36 25 mm mineral wool 50-67 cross-flow aluminium -25 ... +40 2100 876 15000 15876 5.3 27 21.7 - - -
- - - aluzinc - - - - - - - - - - - - - - - - - - - - 50/60 1 NRVU 140 315 G4 G4 2920 230 water heating 36 25 mm mineral wool 50-67 cross-flow aluminium -25 ... +40 2100 - - - - - - 2 5.3 876
- - - aluzinc - - - - - - - - - - - - - option - - - - - - 50/60 3 NRVU 281 400 G4 G4 3400 400 electric heating 46 25 mm mineral wool 59-72 cross-flow aluminium -25 ... +40 4300 2226 21000 23226 3.5 33.5 30 - - -
- - - aluzinc - - - - - - - - - - - - - option - - - - - - 50/60 3 NRVU 268 400 G4 G4 3400 400 water heating 46 25 mm mineral wool 59-72 cross-flow aluminium -25 ... +40 4300 - - - - - - 2 3.5 2226
min mixed-flow Inline plastic for round air ducts 250 125 1110 IP X4 47 - 1~230 7.8 0.54 50/60 60 1955 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
max mixed-flow Inline plastic for round air ducts 250 177 1400 IP X4 55 - 1~230 7.8 0.79 50/60 60 2440 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
min mixed-flow Inline plastic for round air ducts 150 42 415 IP X4 37 B 1~230 2.3 - 50/60 60 1940 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). 0.19 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
max mixed-flow Inline plastic for round air ducts 150 50 565 IP X4 46 B 1~230 2.3 - 50/60 60 2620 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). 0.22 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
min mixed-flow Inline plastic for round air ducts 200 76 830 IP X4 45 B 1~230 3.95 - 50/60 60 1915 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). 0.34 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
max mixed-flow Inline plastic for round air ducts 200 108 1040 IP X4 52 B 1~230 3.95 - 50/60 60 2380 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). 0.48 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
min mixed-flow Inline plastic for round air ducts 315 320 1570 IP X4 49 - 1~230 11.95 - 50/60 60 1890 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). 1 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
max mixed-flow Inline plastic for round air ducts 315 320 2050 IP X4 58 - 1~230 11.95 - 50/60 60 2430 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). 1.42 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- mixed-flow Inline plastic for round air ducts 125 25 240 IP X4 29 B 1~230 2.15 0.11 50/60 60 1630 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- mixed-flow Inline plastic for round air ducts 125 29 350 IP X4 34 B 1~230 2.15 0.13 50/60 60 2300 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
max mixed-flow Inline plastic for round air ducts 160 50 565 IP X4 46 B 1~230 3.25 - 50/60 60 2620 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). 0.22 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
min mixed-flow Inline plastic for round air ducts 160 42 415 IP X4 37 B 1~230 3.25 - 50/60 60 1940 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). 0.19 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
min mixed-flow Inline plastic for round air ducts 100 23 180 IP X4 27 C 1~230 1.75 0.10 60 - 2050 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
max mixed-flow Inline plastic for round air ducts 100 25 245 IP X4 32 C 1~230 1.75 0.11 50/60 - 2620 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Min speed mixed-flow Inline polymer for round air ducts 200 - 752 IP X4 37 - 1~230 - - 50 -25...+55 1866 - - - 209 82 0.37 IP 20 - - - - - - - - - - - - - - - - - - - - - - - - - -
Mid speed mixed-flow Inline polymer for round air ducts 200 - 978 IP X4 40 - 1~230 - - 50 -25...+55 2400 - - - 272 101 0.45 IP 20 - - - - - - - - - - - - - - - - - - - - - - - - - -
Max speed mixed-flow Inline polymer for round air ducts 200 - 1140 IP X4 42 - 1~230 - - 50 -25...+55 2738 - - - 317 113 0.51 IP 20 - - - - - - - - - - - - - - - - - - - - - - - - - -
Min speed mixed-flow Inline polymer for round air ducts 250 - 1038 IP X4 39 - 1~230 - - 50 -25...+55 2292 - - - 288 144 0.70 IP 20 - - - - - - - - - - - - - - - - - - - - - - - - - -
Mid speed mixed-flow Inline polymer for round air ducts 250 - 1447 IP X4 41 - 1~230 - - 50 -25...+55 2626 - - - 402 173 0.81 IP 20 - - - - - - - - - - - - - - - - - - - - - - - - - -
Max speed mixed-flow Inline polymer for round air ducts 250 - 1715 IP X4 43 - 1~230 - - 50 -25...+55 2876 - - - 476 188 0.84 IP 20 - - - - - - - - - - - - - - - - - - - - - - - - - -
Min speed mixed-flow Inline polymer for round air ducts 150 , 160 - 488 IP X4 34 - 1~230 - - 50 -25...+55 2550 - - - 136 34 0.15 IP 20 - - - - - - - - - - - - - - - - - - - - - - - - - -
Mid speed mixed-flow Inline polymer for round air ducts 150 , 160 - 544 IP X4 35 - 1~230 - - 50 -25...+55 2704 - - - 151 37 0.16 IP 20 - - - - - - - - - - - - - - - - - - - - - - - - - -
Max speed mixed-flow Inline polymer for round air ducts 150 , 160 - 600 IP X4 37 - 1~230 - - 50 -25...+55 2816 - - - 167 45 0.20 IP 20 - - - - - - - - - - - - - - - - - - - - - - - - - -
Min speed mixed-flow Inline polymer for round air ducts 355 - 1277 IP X4 37 - 1~230 - - 60 -25...+55 - - - 996 355 90 0.43 IP 20 - - - - - - - - - - - - - - - - - - - - - - - - - -
Mid speed mixed-flow Inline polymer for round air ducts 355 - 1771 IP X4 38 - 1~230 - - 60 -25...+55 - - - 1360 492 128 0.60 IP 20 - - - - - - - - - - - - - - - - - - - - - - - - - -
Max speed mixed-flow Inline polymer for round air ducts 355 - 2600 IP X4 43 - 1~230 - - 60 -25...+55 - - - 1632 722 182 0.85 IP 20 - - - - - - - - - - - - - - - - - - - - - - - - - -
Min speed mixed-flow Inline polymer for round air ducts 355 - 2090 IP X4 38 - 1~230 - - 50 -25...+55 - - - 1350 581 126 0.60 IP 20 - - - - - - - - - - - - - - - - - - - - - - - - - -
Mid speed mixed-flow Inline polymer for round air ducts 355 - 2296 IP X4 38 - 1~230 - - 50 -25...+55 - - - 1400 638 131 0.58 IP 20 - - - - - - - - - - - - - - - - - - - - - - - - - -
Max speed mixed-flow Inline polymer for round air ducts 355 - 2485 IP X4 43 - 1~230 - - 50 -25...+55 - - - 1470 690 150 0.66 IP 20 - - - - - - - - - - - - - - - - - - - - - - - - - -
Min speed mixed-flow Inline polymer for round air ducts 400 - 2677 IP X4 40 - 1~230 - 0.91 50 -25...+55 - - - 1320 744 197 - IP 20 - - - - - - - - - - - - - - - - - - - - - - - - - -
Mid speed mixed-flow Inline polymer for round air ducts 400 - 3136 IP X4 42 - 1~230 - 0.90 50 -25...+55 - - - 1390 871 204 - IP 20 - - - - - - - - - - - - - - - - - - - - - - - - - -
Max speed mixed-flow Inline polymer for round air ducts 400 - 3350 IP X4 43 - 1~230 - 0.98 50 -25...+55 - - - 1446 931 224 - IP 20 - - - - - - - - - - - - - - - - - - - - - - - - - -
Min speed mixed-flow Inline polymer for round air ducts 400 - 1846 IP X4 38 - 1~230 - - 60 -25...+55 - - - 1000 513 146 0.73 IP 20 - - - - - - - - - - - - - - - - - - - - - - - - - -
Mid speed mixed-flow Inline polymer for round air ducts 400 - 2401 IP X4 42 - 1~230 - - 60 -25...+55 - - - 1320 667 208 1.00 IP 20 - - - - - - - - - - - - - - - - - - - - - - - - - -
Max speed mixed-flow Inline polymer for round air ducts 400 - 3390 IP X4 43 - 1~230 - - 60 -25...+55 - - - 1566 942 300 1.40 IP 20 - - - - - - - - - - - - - - - - - - - - - - - - - -
- mixed-flow Inline polymer for round air ducts 200 - 1250 IP X4 50 - 1~ 220-240 - 0.96 50/60 -25...+55 - - - 3110 347 121 - IP44 - - - - - - - - - - - - - - - - - - - - - - - - - -
- mixed-flow Inline polymer for round air ducts 315 - 3250 IP X4 55 - 220-240 - 1.56 50 -25...+55 - - - 2424 903 353 - IP44 - - - - - - - - - - - - - - - - - - - - - - - - - -