Login

Privacy Policy (GDPR)
Authorization
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Product consultation from our experts - Online
Registration
Signup
By using this form, you confirm that you have read the site terms of use Terms of use and completely accept the terms of use
Print version
Search results
Selected products
Mode Minimum air capacityCurrentPowerHeatingDuctConnection diameterSpeedFrequencyDesignMountingTypeCurrentVoltagePower consumptionSound pressure level at 3 mSpigot sizeWeightAir capacityIP CodeRPMPhaseFrequencyNumber of water (glycol) coil rowsConnection diameter of the heat exchangerMaximum fan powerFan currentMaximum water temperatureTransported air temperatureCasing materialInsulationFilterConnected air duct sizeWeightVoltageVoltageFrequency Power consumptionCurrent Maximum air capacityMaximum air capacity RPMSound pressure level at 3 m distanceTransported air temperatureMotor protection ratingPhase
- 90 5.2 1200 electric reheating for round air ducts 125 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- 80 3.5 800 electric reheating for round air ducts 150 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- 90 5.2 1200 electric reheating for round air ducts 150 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- 160 7.4 1700 electric reheating for round air ducts 150 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- 170 8.7 2000 electric reheating for round air ducts 150 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- 80 3.5 800 electric reheating for round air ducts 160 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- 150 5.2 1200 electric reheating for round air ducts 160 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- 160 7.4 1700 electric reheating for round air ducts 160 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- 170 8.7 2000 electric reheating for round air ducts 160 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- 150 5.2 1200 electric reheating for round air ducts 200 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- 160 7.4 1700 electric reheating for round air ducts 200 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- 170 8.7 2000 electric reheating for round air ducts 200 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- 180 5.2 1200 electric reheating for round air ducts 250 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- 200 8.7 2000 electric reheating for round air ducts 250 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- 375 13.0 3000 electric reheating for round air ducts 250 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- 220 8.7 2000 electric reheating for round air ducts 315 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- 320 13.0 3000 electric reheating for round air ducts 315 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
min - - - - - - min 50/60 mixed-flow wall mounting , ceiling mounting exhaust 0.03 220-240 1.5 21 100 0.66 58 IP 45 1850 - - - - - - - - - - - - - - - - - - - - - - - - -
max - - - - - - max 50/60 mixed-flow wall mounting , ceiling mounting exhaust 0.04 220-240 2.7 26 100 0.66 93 IP 45 2650 - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - water heating for round air ducts - - - - floor mounting , wall mounting , ceiling mounting - - - - 44 - - 800 - - 1 50 4 3/4 139 1.05 150 -30...+40 aluzinc 30 mm mineral wool Coarce 90% / G4 (option ePM1 70% / F7) 250 27 230 - - - - - - - - - - -
- - - - water heating for rectangular air ducts - - - - floor mounting , wall mounting , ceiling mounting - - - - 48 - - 920 - - 1 50 4 1 165 1.23 150 -30...+40 aluzinc 30 mm mineral wool Coarce 90% / G4 (option ePM1 70% / F7) 400х200 35 230 - - - - - - - - - - -
- - - - water heating for rectangular air ducts - - - - floor mounting , wall mounting , ceiling mounting - - - - 49 - - 1445 - - 1 50 4 1 222 1.6 150 -30...+40 aluzinc 30 mm mineral wool Coarce 90% / G4 (option ePM1 70% / F7) 500х250 49 230 - - - - - - - - - - -
- - - - water heating for rectangular air ducts - - - - floor mounting , wall mounting , ceiling mounting - - - - 53 - - 2150 - - 1 50 4 1 387 1.7 150 -30...+40 aluzinc 30 mm mineral wool Coarce 90% / G4 (option ePM1 70% / F7) 500х300 45 230 - - - - - - - - - - -
- - - - water heating for rectangular air ducts - - - - floor mounting , wall mounting , ceiling mounting - - - - 52 - - 2930 - - 1 50 4 1 1/8 425 1.8 150 -30...+40 aluzinc 30 mm mineral wool Coarce 90% / G4 (option ePM1 70% / F7) 600х300 50 230 - - - - - - - - - - -
- - - - water heating for rectangular air ducts - - - - floor mounting , wall mounting , ceiling mounting - - - - 54 - - 4950 - - 1 50 4 1 3/8 698 1.06 150 -30...+40 aluzinc 30 mm mineral wool Coarce 90% / G4 (option ePM1 70% / F7) 700х400 58 230 - - - - - - - - - - -
- - - - - - 210 - - - - - - - - - - 2.04 - IP X5 - - - - - - - - - - - - - - - 230 50/60 55 0.4 271 975 2780 50 -25 ... +60 IP55 1
Share your opinion

Questionnaire
How often do you use equipment selection program?