Mode IP CodeVoltageEngine TypeFrequencyPower consumptionCurrentRPMSound pressure level at 3 mWeightDuct diameterDesignMountingTypeAir capacitySFPMaximum air capacitySpigot sizeCasing materialDuctEC motorPhaseVoltageSound pressure level at 3 m distanceProtection ratingMax. transported air temperatureCurrentMaximum air capacity Frequency RPMPower consumptionWeightSEC Class*SEC ClassLamp powerSpeed
- - - - - - - - - - 355 mixed-flow Inline - - - - - polymer coated steel for round air ducts yes 1 1~200-277 61 IP X4 -25 +40 2.5 4080 50/60 1700 460 - - - - - -
- IP 24 220 220V / 50-60Hz 50/60 5 0.048 2300 35 0.44 125 axial wall mounting , ceiling mounting exhaust 82 - - 125 - - - - - - - - - - - - - - - - - - -
- IP 24 220 220V / 50-60Hz 50/60 5 0.049 2200 34 0.49 125 axial wall mounting , ceiling mounting exhaust 78 - - 125 - - - - - - - - - - - - - - - - - - -
- IP 24 220 220V / 50-60Hz 50/60 5 0.048 2285 35 0.5 125 axial wall mounting , ceiling mounting exhaust 80 - - 125 - - - - - - - - - - - - - - - - - - -
max IP 45 230 220V / 50-60Hz 50/60 7.5 0.052 - 25 0.55 100 axial wall mounting exhaust 90 - - 100 - - - - - - - - - - - - - - - - - - -
min IP 45 230 220V / 50-60Hz 50/60 4 0.029 - 22 0.55 100 axial wall mounting exhaust 60 - - 100 - - - - - - - - - - - - - - - - - - -
max IP 45 230 220V / 50-60Hz 50/60 13.5 0.09 - 32 0.78 125 axial wall mounting exhaust 170 - - 125 - - - - - - - - - - - - - - - - - - -
min IP 45 230 220V / 50-60Hz 50/60 9.5 0.065 - 28 0.78 125 axial wall mounting exhaust 145 - - 125 - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - 100 centrifugal Inline - - - - - plastic for round air ducts yes - 1~230 40 IP X4 -25 +60 0.62 340 50/60 3400 82 2 B To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). - - -
- - - - - - - - - - 250 centrifugal Inline - - - - - plastic for round air ducts yes - 1~230 48 IP X4 -25 +60 1.10 1250 50/60 2600 165 4.3 - To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). - - -
- - - - - - - - - - 100 mixed-flow Inline - - - - - low-combustible polypropylene for round air ducts yes - 1~230 47 IP X4 -25...+55 0.29 300 50 3680 30 1.75 B To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). - - -
50 Hz, Speed 1 IP X4 220-240 - 50 23 0.12 756 25 - - - - - 170 0.49 47 - - - - - - - - - - - - - - - - - C 2 х 10 1
50 Hz, Speed 2 IP X4 220-240 - 50 39 0.18 1122 29 - - - - - 260 0.54 72 - - - - - - - - - - - - - - - - - C 2 х 10 2
60 Hz, Speed 1 IP X4 220-240 - 60 25 0.14 732 25 - - - - - 160 0.56 44 - - - - - - - - - - - - - - - - - C 2 х 10 1
60 Hz, Speed 2 IP X4 220-240 - 60 50 0.22 1140 30 - - - - - 270 0.67 75 - - - - - - - - - - - - - - - - - C 2 х 10 2
50 Hz, Speed 1 IP X4 220-240 - 50 31 0.15 936 28 - - - - - 220 0.51 83 - - - - - - - - - - - - - - - - - C 2 х 10 1
50 Hz, Speed 2 IP X4 220-240 - 50 49 0.22 1254 31 - - - - - 300 0.59 83 - - - - - - - - - - - - - - - - - C 2 х 10 2
60 Hz, Speed 1 IP X4 220-240 - 60 35 0.17 888 27 - - - - - 200 0.63 56 - - - - - - - - - - - - - - - - - C 2 х 10 1
60 Hz, Speed 2 IP X4 220-240 - 60 63 0.28 1320 32 - - - - - 320 0.71 89 - - - - - - - - - - - - - - - - - C 2 х 10 2
50 Hz, Speed 1 IP X4 220-240 - 50 20 0.1 714 24 - - - - - 130 0.55 36 - - - - - - - - - - - - - - - - - D - 1
50 Hz, Speed 2 IP X4 220-240 - 50 29 0.13 1026 27 - - - - - 210 0.5 58 - - - - - - - - - - - - - - - - - D - 2
60 Hz, Speed 1 IP X4 220-240 - 60 21 0.11 588 24 - - - - - 130 0.58 36 - - - - - - - - - - - - - - - - - D - 1
60 Hz, Speed 2 IP X4 220-240 - 60 34 0.15 936 28 - - - - - 225 0.54 63 - - - - - - - - - - - - - - - - - D - 2
50 Hz, Speed 1 IP X4 220-240 - 50 23 0.12 756 25 - - - - - 170 0.49 47 - - - - - - - - - - - - - - - - - C - 1
50 Hz, Speed 2 IP X4 220-240 - 50 39 0.18 1122 29 - - - - - 260 0.54 72 - - - - - - - - - - - - - - - - - C - 2
60 Hz, Speed 1 IP X4 220-240 - 60 25 0.14 732 25 - - - - - 160 0.56 44 - - - - - - - - - - - - - - - - - C - 1
60 Hz, Speed 2 IP X4 220-240 - 60 50 0.22 1140 30 - - - - - 270 0.67 75 - - - - - - - - - - - - - - - - - C - 2
50 Hz, Speed 1 IP X4 220-240 - 50 31 0.15 936 28 - - - - - 220 0.51 61 - - - - - - - - - - - - - - - - - C - 1
50 Hz, Speed 2 IP X4 220-240 - 50 49 0.22 1254 31 - - - - - 300 0.59 83 - - - - - - - - - - - - - - - - - C - 2
60 Hz, Speed 1 IP X4 220-240 - 60 35 0.17 888 27 - - - - - 200 0.63 56 - - - - - - - - - - - - - - - - - C - 1
60 Hz, Speed 2 IP X4 220-240 - 60 63 0.28 1320 32 - - - - - 320 0.71 89 - - - - - - - - - - - - - - - - - C - 2
- IP X4 120-240 - 50/60 19 0.18 (0.3) 1100 23...25 - - - - - 187 0.37 52 - - - - - - - - - - - - - - - - - C 2 х 10 -
- IP X4 120-240 - 50/60 26 0.24 (0.39) 1100 23...29 - - - - - 254 0.37 71 - - - - - - - - - - - - - - - - - C 2 х 10 -
- IP X4 120-240 - 50/60 19 0.18 (0.3) 1100 23...25 - - - - - 187 0.37 52 - - - - - - - - - - - - - - - - - C - -
- IP X4 120-240 - 50/60 26 0.24 (0.39) 1100 23...29 - - - - - 254 0.37 71 - - - - - - - - - - - - - - - - - C - -
- IP 44 230 - 50 7.5 0.05 2000 25 0.51 - axial wall mounting , ceiling mounting exhaust 85 - - 100 - - - - - - - - - - - - - - - - - - -
- IP 44 230 - 60 7.5 0.05 2000 25 0.51 - axial wall mounting , ceiling mounting exhaust 85 - - 100 - - - - - - - - - - - - - - - - - - -
- IP 44 230 - 50 7.5 0.05 2000 25 0.51 - axial wall mounting , ceiling mounting exhaust 85 - - 100 - - - - - - - - - - - - - - - - - - -
- IP 44 230 - 60 7.5 0.05 2000 25 0.51 - axial wall mounting , ceiling mounting exhaust 85 - - 100 - - - - - - - - - - - - - - - - - - -
- IP 44 220 - 60 18 0.11 2200 32 0.75 - axial wall mounting , ceiling mounting exhaust 155 - - 125 - - - - - - - - - - - - - - - - - - -
- IP 44 12 - 50 9 1.06 1950 26 0.51 - axial wall mounting , ceiling mounting exhaust 80 - - 100 - - - - - - - - - - - - - - - - - - -
- IP 44 220-240 - 50 18 0.11 2200 32 0.75 - axial wall mounting , ceiling mounting exhaust 155 - - 125 - - - - - - - - - - - - - - - - - - -
- IP 44 220 - 60 8 0.05 2000 27 0.51 - axial wall mounting , ceiling mounting exhaust 85 - - 100 - - - - - - - - - - - - - - - - - - -
- IP 44 220-240 - 50 8 0.05 2000 27 0.51 - axial wall mounting , ceiling mounting exhaust 85 - - 100 - - - - - - - - - - - - - - - - - - -
max IP 45 230 220V / 50-60Hz 50/60 3.6 0.137 2150 26.5 0.55 100 axial wall mounting , ceiling mounting exhaust 100 - - 100 - - - - - - - - - - - - - - - - - - -
min IP 45 230 220V / 50-60Hz 50/60 1.7 0.063 1800 22 0.55 100 axial wall mounting , ceiling mounting exhaust 70 - - 100 - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - 160 mixed-flow Inline - - - - - low-combustible polypropylene for round air ducts yes - 1~230 46 IP X4 -25...+55 0.48 600 50 3390 55 3.25 B To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). - - -
- - - - - - - - - - 315 mixed-flow Inline - - - - - low-combustible polypropylene for round air ducts yes - 1~230 55 IP X4 -25...+55 1.25 1970 50 2826 284 11.95 - To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). - - -
- - - - - - - - - - 150 mixed-flow Inline - - - - - low-combustible polypropylene for round air ducts yes - 1~230 46 IP X4 -25...+55 0.48 600 50 3390 55 2.95 B To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). - - -
- - - - - - - - - - 200 mixed-flow Inline - - - - - low-combustible polypropylene for round air ducts yes - 1~230 49 IP X4 -25...+55 1.02 1040 50 3390 123 3.95 - To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). - - -
- - - - - - - - - - 125 mixed-flow Inline - - - - - low-combustible polypropylene for round air ducts yes - 1~230 49 IP X4 -25...+55 0.37 450 50 3750 40 2.15 B To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). - - -
- - - - - - - - - - 250 mixed-flow Inline - - - - - low-combustible polypropylene for round air ducts yes - 1~230 53 IP X4 -25...+55 1.38 1285 50 2870 169 7.80 - To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). - - -
- IP X4 220-240 220-240V / 50Hz or 220-240V / 60Hz 50; 60 22 0.095 2250 39 1.3 150 axial Inline exhaust , supply 335 - - 150 - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - 315 centrifugal Inline - - - - - plastic for round air ducts yes - 1~230 48 IP X4 -25 +60 1.15 1500 50/60 2500 165 4.9 - To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). - - -
- - - - - - - - - - 200 centrifugal Inline - - - - - plastic for round air ducts yes - 1~230 47 IP X4 -25 +60 0.64 885 50/60 2700 84 3 B To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). - - -
- - - - - - - - - - 150 centrifugal Inline - - - - - plastic for round air ducts yes - 1~230 45 IP X4 -25 +60 0.63 630 50/60 3400 82 2.5 B To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). - - -
- IP X4 220-240 220-240V / 50Hz or 220-240V / 60Hz 50; 60 7.5 0.049 2100 25 0.61 100 axial Inline exhaust , supply 100 - - 100 - - - - - - - - - - - - - - - - - - -
max IP X4 220-240 220-240V / 50Hz or 220-240V / 60Hz 50; 60 7.5 0.049 2100 25 0.61 100 axial Inline exhaust , supply 100 - - 100 - - - - - - - - - - - - - - - - - - -
min IP X4 220-240 220-240V / 50Hz or 220-240V / 60Hz 50; 60 4.5 0.029 1650 22 0.61 100 axial Inline exhaust , supply 75 - - 100 - - - - - - - - - - - - - - - - - - -
- IP X4 12 12V / 50Hz or 12V / 60Hz 50; 60 7.5 0.99 2100 25 0.61 100 axial Inline exhaust , supply 100 - - 100 - - - - - - - - - - - - - - - - - - -
- IP X4 12 12V / 50Hz or 12V / 60Hz 50; 60 7.5 0.99 2100 25 0.61 100 axial Inline exhaust , supply 100 - - 100 - - - - - - - - - - - - - - - - - - -
max IP X4 220-240 220-240V / 50Hz or 220-240V / 60Hz 50; 60 7.5 0.049 2100 25 0.61 100 axial Inline exhaust , supply 100 - - 100 - - - - - - - - - - - - - - - - - - -
min IP X4 220-240 220-240V / 50Hz or 220-240V / 60Hz 50; 60 4.5 0.029 1650 22 0.61 100 axial Inline exhaust , supply 75 - - 100 - - - - - - - - - - - - - - - - - - -
- IP X4 220-240 220-240V / 50Hz or 220-240V / 60Hz 50; 60 7.5 0.049 2100 25 0.61 100 axial Inline exhaust , supply 100 - - 100 - - - - - - - - - - - - - - - - - - -
max IP X4 220-240 220-240V / 50-60Hz 50/60 25 0.109 2600 41 1.3 150 axial Inline exhaust , supply 375 - - 150 - - - - - - - - - - - - - - - - - - -
min IP X4 220-240 220-240V / 50-60Hz 50/60 22 0.103 2300 36 1.3 150 axial Inline exhaust , supply 285 - - 150 - - - - - - - - - - - - - - - - - - -
max IP X4 220-240 220-240V / 50-60Hz 50/60 22 0.095 2250 39 1.3 150 axial Inline exhaust , supply 335 - - 150 - - - - - - - - - - - - - - - - - - -
min IP X4 220-240 220-240V / 50-60Hz 50/60 19 0.087 1950 36 1.3 150 axial Inline exhaust , supply 250 - - 150 - - - - - - - - - - - - - - - - - - -
- IP X4 220-240 220-240V / 50Hz or 220-240V / 60Hz 50; 60 26 0.085 1900 37 1.3 150 axial Inline exhaust , supply 305 - - 150 - - - - - - - - - - - - - - - - - - -
- IP 44 220-240 220-240V / 50Hz 50 9 0.059 2165 25 0.55 100 axial wall mounting exhaust 97 0.33 27 - - - - - - - - - - - - - - - - - - - -
- IP X4 220-240 220-240V / 50Hz or 220-240V / 60Hz 50; 60 13 0.085 2250 32 0.75 125 axial Inline exhaust , supply 197 - - 125 - - - - - - - - - - - - - - - - - - -
- IP X4 220-240 220-240V / 50Hz or 220-240V / 60Hz 50; 60 13 0.085 2250 32 0.75 125 axial Inline exhaust , supply 197 - - 125 - - - - - - - - - - - - - - - - - - -