Mode DesignMountingCasing materialDuctDuct diameterPower consumptionMaximum air capacity Protection ratingSound pressure level at 3 m distanceSEC ClassVoltageWeightCurrentFrequency Max. transported air temperatureRPM*CurrentTypePower consumptionCurrentWeightVoltageSpigot sizeIP CodeEngine TypeFrequencySound pressure level at 3 mRPMAir capacityAir capacityWeightMaximum air capacitySFPSEC ClassLamp powerSpecific power
- axial wall mounting , ceiling mounting - - 125 - - - - - - - - - - - - - exhaust 24 0.105 1.18 220-240 125 IP 34 220-240V / 50-60Hz 50/60 36 2400 209 - - - - - - -
- axial wall mounting , ceiling mounting - - 150 - - - - - - - - - - - - - exhaust 30 0.13 1.49 220-240 150 IP 34 220-240V / 50Hz or 220-240V / 60Hz 50; 60 39 2400 310 - - - - - - -
- axial wall mounting , ceiling mounting - - 100 - - - - - - - - - - - - - exhaust 14 1.5 0.88 12 100 IP 34 12V / 50-60Hz 50/60 32 2200 77 - - - - - - -
- axial wall mounting , ceiling mounting - - 125 - - - - - - - - - - - - - exhaust 16 1.7 1.06 12 125 IP 34 12V / 50-60Hz 50/60 33 2300 149 - - - - - - -
- axial wall mounting , ceiling mounting - - 150 - - - - - - - - - - - - - exhaust 29 2 1.31 12 150 IP 34 12V / 50Hz or 12V / 60Hz 50; 60 36 2300 236 - - - - - - -
- axial wall mounting , ceiling mounting - - - - - - - - - 0.97 - - - - - - exhaust 28 0.21 - 220-240 150 IP 44 - 50 35 - - 255 - 71 - - - 0.39
- axial wall mounting , ceiling mounting - - 100 - - - - - - - - - - - - - exhaust 14 0.090 - 220-240 100 IP 24 220-240V / 50-60Hz 50/60 33 2300 - 92 0.60 - - - - -
- axial wall mounting , ceiling mounting - - 100 - - - - - - - - - - - - - exhaust 17 0.121 - 220-240 100 IP 24 220-240V / 50-60Hz 50/60 37 2500 - 115 0.68 - - - - -
- axial wall mounting , ceiling mounting - - 100 - - - - - - - - - - - - - exhaust 14 1.650 - 12 100 IP 24 - 50 32 2100 - 80 0.59 - - - - -
- axial wall mounting , ceiling mounting - - 125 - - - - - - - - - - - - - exhaust 17.5 0.117 - 220-240 125 IP 24 220-240V / 50-60Hz 50/60 35 2400 - 174 0.74 - - - - -
- axial wall mounting , ceiling mounting - - 125 - - - - - - - - - - - - - exhaust 21 0.132 - 220-240 125 IP 24 220-240V / 50-60Hz 50/60 37 2500 - 217 0.84 - - - - -
- axial wall mounting , ceiling mounting - - 100 - - - - - - - - - - - - - exhaust 14 0.090 - 220-240 100 IP 24 220-240V / 50-60Hz 50/60 33 2300 - 92 0.60 - - - - -
- axial wall mounting , ceiling mounting - - 100 - - - - - - - - - - - - - exhaust 17 0.121 - 220-240 100 IP 24 220-240V / 50-60Hz 50/60 37 2500 - 115 0.68 - - - - -
- axial wall mounting , ceiling mounting - - 100 - - - - - - - - - - - - - exhaust 14 1.650 - 12 100 IP 24 - 50 32 2100 - 80 0.59 - - - - -
- axial wall mounting , ceiling mounting - - 125 - - - - - - - - - - - - - exhaust 17.5 0.117 - 220-240 125 IP 24 220-240V / 50-60Hz 50/60 35 2400 - 174 0.74 - - - - -
- axial wall mounting , ceiling mounting - - 125 - - - - - - - - - - - - - exhaust 21 0.132 - 220-240 125 IP 24 220-240V / 50-60Hz 50/60 37 2500 - 217 0.84 - - - - -
- - ceiling mounting - - 100 - - - - - - - - - - - - - - 19 0.18 (0.3) - 120-240 - - - 50/60 23-25 1100 - 187 - 52 0.37 C - -
- - ceiling mounting - - 100 - - - - - - - - - - - - - - 19 0.18 (0.3) - 120-240 - - - 50/60 23-25 1100 - 187 - 52 0.37 C 2 x 10 -
- mixed-flow Inline plastic for round air ducts 125 25 240 IP X4 29 B 1~230 2.15 0.11 50/60 60 1630 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). - - - - - - - - - - - - - - - - - - - -
- mixed-flow Inline plastic for round air ducts 125 29 350 IP X4 34 B 1~230 2.15 0.13 50/60 60 2300 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). - - - - - - - - - - - - - - - - - - - -
min mixed-flow Inline plastic for round air ducts 150 42 415 IP X4 37 B 1~230 2.3 - 50/60 60 1940 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). 0.19 - - - - - - - - - - - - - - - - - - -
max mixed-flow Inline plastic for round air ducts 150 50 565 IP X4 46 B 1~230 2.3 - 50/60 60 2620 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). 0.22 - - - - - - - - - - - - - - - - - - -
min mixed-flow Inline plastic for round air ducts 200 76 830 IP X4 45 B 1~230 3.95 - 50/60 60 1915 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). 0.34 - - - - - - - - - - - - - - - - - - -
max mixed-flow Inline plastic for round air ducts 200 108 1040 IP X4 52 B 1~230 3.95 - 50/60 60 2380 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). 0.48 - - - - - - - - - - - - - - - - - - -
min mixed-flow Inline plastic for round air ducts 315 320 1570 IP X4 49 - 1~230 11.95 - 50/60 60 1890 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). 1 - - - - - - - - - - - - - - - - - - -
max mixed-flow Inline plastic for round air ducts 315 320 2050 IP X4 58 - 1~230 11.95 - 50/60 60 2430 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). 1.42 - - - - - - - - - - - - - - - - - - -
min mixed-flow Inline plastic for round air ducts 250 125 1110 IP X4 47 - 1~230 7.8 0.54 50/60 60 1955 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). - - - - - - - - - - - - - - - - - - - -
max mixed-flow Inline plastic for round air ducts 250 177 1400 IP X4 55 - 1~230 7.8 0.79 50/60 60 2440 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). - - - - - - - - - - - - - - - - - - - -
max mixed-flow Inline plastic for round air ducts 160 50 565 IP X4 46 B 1~230 3.25 - 50/60 60 2620 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). 0.22 - - - - - - - - - - - - - - - - - - -
min mixed-flow Inline plastic for round air ducts 160 42 415 IP X4 37 B 1~230 3.25 - 50/60 60 1940 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). 0.19 - - - - - - - - - - - - - - - - - - -
min mixed-flow Inline plastic for round air ducts 100 23 180 IP X4 27 C 1~230 1.75 0.10 60 - 2050 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). - - - - - - - - - - - - - - - - - - - -
max mixed-flow Inline plastic for round air ducts 100 25 245 IP X4 32 C 1~230 1.75 0.11 50/60 - 2620 To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). - - - - - - - - - - - - - - - - - - - -