VENTS VUT 300 E2V EC air handling units with heat recovery

VENTS VUT 300 E2V EC air handling units with heat recovery

Air handling units with heat recovery for cold climate. Air capacity up to 300 m3/h. Heat recovery efficiency up to 95%.

Voltage / frequency:

OK

Products in this series (2)

  • VUT 300 E2V EC

    VUT 300 E2V EC

    VUT 300-2 E2V EC

    VUT 300-2 E2V EC

Series   Rated air capacity, m3/h   Air ducts diameter   Heater type and number   Duct connection   Motor type
VENTS VUT
  300   _ – 150
2 – 160
  E2 - electric heater, 2 items   V - vertical   EC - synchronous electronically commutated motor
Description

The air handling unit VUT 300 E2V EC with heat recovery is the fully-featured ventilation unit which ensures air filtration, fresh air supply and stale air extract.

The heat contained in the extract air is recuperated in the plate counter-flow heat exchanger to warm up supply air.

The unit is designed for energy efficient ventilation of cottages and flats in the cold climatic conditions.

The heat exchanger freezing protection is ensured due to the pre-heating electric heater on the intake side.

Compatible with round Ø 150 or 160 mm air ducts.

Unit design

Casing

Made of double-skinned aluzinc, internally filled with 20 mm mineral wool heat- and sound-insulating layer.

Filter

Supply and extract air flows are purified through two bag filters with filtering class G4. A replaceable filter with filtering class F7 is optionally available.

Fans

High-efficient electronically-commutated direct current motors with external motor and impellers with backward curved blades.

Such motors are the most state-of-the-art energy-saving solution. EC motors are featured with high performance and total speed controllable range.

Any of three fan speeds may be adjusted with the remote controller. The supply and extract fan speeds are adjustable during the system setup.

Heat exchanger

Counter-flow polystyrene heat exchangers with high heat recovery efficiency (up to 95%). The drain pan under the heat exchanger block ensures condensate removal.

The heat exchanger has freezing protection with the electric heater on the intake side.

The special heat exchanger freeze protection logic provides temporary fan speed slowdown at the outdoor temperatures below -30 °C if the pre-heating power is not sufficient to maintain the best heat recovery efficiency.

The removable heat exchanger facilitates cleaning.

Heater

The unit is exchanged with two electric heaters. The first heater is located upstream of the heat exchanger to heat the intake air up to the temperature that excludes the heat exchanger freezing and to maintain the maximum heat recovery efficiency.

The second heater is located downstream of the heat exchanger to warm up supply air flow up to the set temperature.

The heating electric elements have active overheating protection controlled by the temperature sensor in the air duct and two overheating thermostats. The first one is actuated at +50 °C and has automatic reset and the second one is actuated at +90 °C and has manual reset. Air supply to the electric heating elements at the end of the heating cycle ensures cooling of the electric heating elements.

Control and automation

The unit is equipped with a control panel with LCD display fixed on 10 m cable. The remote controller is also supplied with the unit as a standard.

Automation functions:

  • Turning the unit on/off from the control panel. Air supply to the electric heating elements during the unit shutdown.
  • Three fans speeds are adjusted during the system setup.
  • Electric pre-heating power regulation function during low outside temperatures. Automatic fan speed slowdown in case of insufficient pre-heating.
  • The electric heater downstream of the heat exchanger ensures maintaining of the set supply temperature. The warming-up temperature is adjusted from +16 °C up to +26 °C. The warming up function may be turned on/off from the remote controller.
  • Connection of automatically driven air dampers is provided.
  • Input for alarm signal from the fire fighting system.
  • Relay input for connection of the CO2 / humidity / IAQ or any other sensor that switches the unit to maximum speed.
  • Filter clogging control by motor hours.
  • Unit week schedule setting.

Controllable ventilation on demand:

The unit is equipped with a contact for relay signal from an external sensor. The unit operation according to an external sensor (for example, CO2 sensor) enables energy demand reducing.

Operation logic of the unit with CO2 sensor: An unoccupied ventilated premise has low CO2 concentration and requires no intensive ventilation. The unit operates at low speed for minimum permanent ventilation.

As people come inside, CO2 concentration in the premise increases and the signal from CO2 sensor closes relay contact.

The unit is turned to maximum speed until CO2 concentration in the room drops down and the contact is opened. After that the unit reverts to the low speed.

To arrange this operating logic it is required to connect any sensor with relay output and to connect it to the respective unit input. The sensor is available upon separate order.

Mounting

The unit is designed for inner mounting in glazed balconies, auxiliary premises, in the attics and is allowed for use at the ambient air temperature not below -15 °C. If the unit is intended to operate at low outside temperatures, its drain pipe must be heat insulated to prevent condensate freezing.

The unit must be fixed to the wall with anchor bolts or mounted on the floor in a position that enables condensate drainage. While mounting the unit provide service access on the front panel side. The panel may be fully removed if required.

Extra accessories

The SR duct silencers are recommended to install in the supply air duct to ensure extra sound attenuation.

Application example

E-mail

Please, feel free to contact us.

support@vents.ua

Phohe

Customer service.

+380 44 406 36 25

Online form

Send a message center customer support.

By using this form you confirm that you have read and agree with the site condition and terms.
Send
  • SR series (round)

    SR series (round)

  • KOM series

    KOM series

  • SRF series

    SRF series

  • C series

    C series

  • BELIMO TF230/TF24

    BELIMO TF230/TF24

  • BELIMO LF230/LF24

    BELIMO LF230/LF24

  • CO2 sensor

    CO2 sensor