VENTS VUT H mini
Air handling units with the air capacity up to 300 m3/h in the compact sound- and heat-insulated casing with horizontal duct connections.
Voltage / frequency: |
Products in this series (4)
Series | Rated air capacity [m3/h] | Duct connection | Type | Integrated automation control | ||||
---|---|---|---|---|---|---|---|---|
VENTS VUT | 200; 300 | H - horizontal | mini | (RS) - A1 (RS-1-400) speed controller |
Description
Air handling units VUT mini are the complete ventilation units designed for air filtration, heating and supply to the premises and removal of exhaust air. The heat of the exhausted air is transferred to the supply air through the plate heat exchanger. All the models are compatible with 100 and 125 mm round ducts.
Modifications
VUT H mini – the models with horizontal duct connections, fans with AC motors.
Casing
Made of aluzinc, internally filled with 20 mm mineral wool heat- and sound-insulating layer.
Filter
Two G4 built-in filters ensure supply and exhaust air fiiltration.
Fans
The unit is equipped with supply and exhaust centrifugal fans with backward curved blades and built-in thermal overheating protection with automatic restart. The electric motors and the impellers are dynamically balanced in two planes.
Heat exchanger
The plate heat exchanger is made of aluminium plates. Whenever heat recovery is not required for unit operation the heat exchanger block can be easily replaced by a “summer” block. The unit is also equipped with the drain pan for condensate drainage as well as with built-in icing protecting system. During operation of the heat exchanger in the winter time the heat from the warm exhaust air is transferred to the cold supply air. During extract air heat energy extraction some condsensate can be generated. If the temperature of the intake air is below -5°С the condensate can get frozen. To prevent the heat exchanger freezing electronic protection system is applied. It switches the supply fan off as the temperature sensor requires. Warm extract air defrosts the heat exchanger, then the supply fan switches on and the unit continues operating under rated conditions.
Control
Switching the unit on and its capacity control is performed with thyristor A1 speed controller (RS-1-400) which provides smooth motor speed control over the range of 0-100%.
Mounting
Air handling unit is mounted on the floor and suspended to the ceiling by means of a seat angle with inserted vibration-damping element or attached to a wall with brackets. The unit can be mounted either in service spaces or in main premises above the suspended ceiling, in the pocket or the unit can be placed directly in the room. Mounting position shall provide correct condensate drainage. Access for maintenance and filter cleaning shall be reserved on the side of the removable side panel on the left from supply air side.