AirVENTS control system provides maximum reliability, easy operation and installation.
- Control system is available in three versions:
- Control block in plastic casing, with external fan VFD and electric heater control;
- Control block in metal casing. Fan speed and triac electric heater controllers (if included) are installed inside the switchboard;
- Plug-and-play unit with all control elements pre-mounted inside the unit.
- Control block provides (depending on model) the following functions:
- Power supply of all the unit elements.
- Active overload protection.
- Operation and error light signals.
- Start and stop of the system.
- Water or electric heater control. The system includes the necessary external and supply air temperature sensors, water (glycol) heater frosting protection sensors, electric heater overheating protection (safety and emergency thermostats).
- Air blowing of electric heaters, water coils pre-heating during cold season.
- Water cooling coil mixing valve or condenser unit block control.
- Smooth bypass valve control of a plate heat exchanger (active frosting protection).
- Air damper actuator control.
- Smooth rotary heat exchanger VFD control.
- Air filters clogging alarm.
- Fan capacity control:
- Smooth regulation, by VFD, which provide soft start, fan stop and overheating protection;
- Stair-step regulation, by an autotransformer;
- Without regulation.
- Demand controlled ventilation, by CO2, temperature, RH level etc.;
- Daily and weekly schedule.
- Air ventilation system shut-down on the fire alarm signal.
- Integration into building management systems through installation of one more interface unit.
|
- Additional option – full electric wiring include:
- Installation of air damper actuators;
- Installation and adjustment of pressure switches in filter sections;
- Installation and adjustment of thermostats and sensors on water heating coils;
- Installation of rotary heat exchanger VFD;
- Installation of bypass damper actuators on plate heat exchangers;
- Mounting triac controls on electric heaters;
- Installation and adjustment of fan VFD;
- Installation and adjustment of all temperature and humidity sensors inside the unit;
- Installation of control block with programmable controller inside the unit, or routing all electric contacts into a single contact block for simple connection to external control block (depending on customers needs).
- Plug-and-play option implies the possibility of shipment in separate blocks. In this case intermediate contact blocks are installed in places where blocks are joined.
|