Login

Privacy Policy (GDPR)
Authorization
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Product consultation from our experts - Online
Registration
Signup
By using this form, you confirm that you have read the site terms of use Terms of use and completely accept the terms of use
Print version
Search results
Selected products
Mode VoltageUV powerUV wavelengthLamp typeRated service life of the lampNumber of lampsSound pressure level at 3 m distanceCurrentPowerFrequency Weight*SpeedVoltageFrequencyRPMWeightSEC ClassMaximum current InsulationCasing materialHeat exchanger typeHeat exchanger materialPowerAir capacityDuctRemote control panelFunctionsHeatingPhaseHeat recovery efficiencyHumidity recovery efficiencyOperating temperatureSound power level LwA to environmentSound pressure level LpA to environment at 1 m distanceSound pressure level LpA to environment at 3 m distanceExtract filter ISO 16890 / EN 779:2012Supply filter ISO 16890 / EN 779:2012TypeConnected air duct diameterSpeedFrequencyDesignMountingCurrentVoltagePower consumptionSound pressure level at 3 mSpigot sizeIP CodeRPMPhaseVoltageFrequencyMaximum unit powerMaximum unit currentSound pressure level at 3 m distanceTransported air temperatureFilter: extractFilter: supplyConnected air duct sizeSEC ClassMax. unit power without electric heaterMax. unit current without electric heaterMax. air capacityRPMConnected air duct diameterHeat recovery efficiencyInsulation thicknessSizeFormHumidity recovery efficiencyMax. unit current with electric heaterElectric preheater powerMaximum unit currentRPMTransported air temperatureConnection diameterInsulationMax. power of electric heaterMax. unit current of electric heaterSound pressure level at 1 m distanceMaximum unit current (with an electric heater)Electric reheater power
- 230 3.8 254 OSRAM HNS S/E 7 W 2G7 8000 2 37 0.132 30 50 3.63 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- 230 1.9 254 OSRAM HNS S/E 7 W 2G7 8000 1 29 0.085 16 50 3.54 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
1 Speed - - - - - - - - - - - Heat recovery efficiency is specified in compliance with EN 13141–8 1 230 50/60 3200 20 A 0.26 10 polymer coated steel counter-flow polystyrene 10 30 100 - - without heating 1 93* - -15...+40 31 20 10 Coarse 90 % / G4 Coarse 90 % / G4. Optional: ePM1 65% / F7 supply and exhaust with heat recovery 2×100 mm + optional 1×100 mm - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
2 Speed - - - - - - - - - - - Heat recovery efficiency is specified in compliance with EN 13141–8 2 230 50/60 3200 20 A 0.26 10 polymer coated steel counter-flow polystyrene 15 60 100 - - without heating 1 87* - -15...+40 41 30 21 Coarse 90 % / G4 Coarse 90 % / G4. Optional: ePM1 65% / F7 supply and exhaust with heat recovery 2×100 mm + optional 1×100 mm - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
3 Speed - - - - - - - - - - - Heat recovery efficiency is specified in compliance with EN 13141–8 3 230 50/60 3200 20 A 0.26 10 polymer coated steel counter-flow polystyrene 31 100 100 - - without heating 1 84* - -15...+40 51 40 31 Coarse 90 % / G4 Coarse 90 % / G4. Optional: ePM1 65% / F7 supply and exhaust with heat recovery 2×100 mm + optional 1×100 mm - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
1 Speed - - - - - - - - - - - Heat recovery efficiency is specified in compliance with EN 13141–8 1 230 50/60 3200 23 A 0.26 10 polymer coated steel , galvanized steel counter-flow polystyrene 10 30 100 - - without heating 1 93* - -15...+40 31 20 10 Coarse 90 % / G4 Coarse 90 % / G4. Optional: ePM1 65% / F7 supply and exhaust with heat recovery 2×100 mm + optional 4×75 mm - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
2 Speed - - - - - - - - - - - Heat recovery efficiency is specified in compliance with EN 13141–8 2 230 50/60 3200 23 A 0.26 10 polymer coated steel , galvanized steel counter-flow polystyrene 15 60 100 - - without heating 1 87* - -15...+40 41 30 21 Coarse 90 % / G4 Coarse 90 % / G4. Optional: ePM1 65% / F7 supply and exhaust with heat recovery 2×100 mm + optional 4×75 mm - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
3 Speed - - - - - - - - - - - Heat recovery efficiency is specified in compliance with EN 13141–8 3 230 50/60 3200 23 A 0.26 10 polymer coated steel , galvanized steel counter-flow polystyrene 31 100 100 - - without heating 1 84* - -15...+40 51 40 31 Coarse 90 % / G4 Coarse 90 % / G4. Optional: ePM1 65% / F7 supply and exhaust with heat recovery 2×100 mm + optional 4×75 mm - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
1 Speed - - - - - - - - - - - Heat recovery efficiency is specified in compliance with EN 13141–8 1 230 50/60 3200 20 A 0.26 10 polymer coated steel counter-flow enthalpy 10 30 100 - - without heating 1 85* 45* -15...+40 31 20 10 Coarse 90 % / G4 Coarse 90 % / G4. Optional: ePM1 65% / F7 supply and exhaust with heat recovery 2×100 mm + optional 1×100 mm - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
2 Speed - - - - - - - - - - - Heat recovery efficiency is specified in compliance with EN 13141–8 2 230 50/60 3200 20 A 0.26 10 polymer coated steel counter-flow enthalpy 15 60 100 - - without heating 1 80* 39* -15...+40 41 30 21 Coarse 90 % / G4 Coarse 90 % / G4. Optional: ePM1 65% / F7 supply and exhaust with heat recovery 2×100 mm + optional 1×100 mm - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
3 Speed - - - - - - - - - - - Heat recovery efficiency is specified in compliance with EN 13141–8 3 230 50/60 3200 20 A 0.26 10 polymer coated steel counter-flow enthalpy 31 100 100 - - without heating 1 72* 29* -15...+40 51 40 31 Coarse 90 % / G4 Coarse 90 % / G4. Optional: ePM1 65% / F7 supply and exhaust with heat recovery 2×100 mm + optional 1×100 mm - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
1 Speed - - - - - - - - - - - Heat recovery efficiency is specified in compliance with EN 13141–8 1 230 50/60 3200 23 A 0.26 10 polymer coated steel , galvanized steel counter-flow enthalpy 10 30 100 - - without heating 1 85* 45* -15...+40 31 20 10 Coarse 90 % / G4 Coarse 90 % / G4. Optional: ePM1 65% / F7 supply and exhaust with heat recovery 2×100 mm + optional 4×75 mm - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
2 Speed - - - - - - - - - - - Heat recovery efficiency is specified in compliance with EN 13141–8 2 230 50/60 3200 23 A 0.26 10 polymer coated steel , galvanized steel counter-flow enthalpy 15 60 100 - - without heating 1 80* 39* -15...+40 41 30 21 Coarse 90 % / G4 Coarse 90 % / G4. Optional: ePM1 65% / F7 supply and exhaust with heat recovery 2×100 mm + optional 4×75 mm - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
3 Speed - - - - - - - - - - - Heat recovery efficiency is specified in compliance with EN 13141–8 3 230 50/60 3200 23 A 0.26 10 polymer coated steel , galvanized steel counter-flow enthalpy 31 100 100 - - without heating 1 72* 29* -15...+40 51 40 31 Coarse 90 % / G4 Coarse 90 % / G4. Optional: ePM1 65% / F7 supply and exhaust with heat recovery 2×100 mm + optional 4×75 mm - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
min - - - - - - - - - - 0.66 - - - - - - - - - - - - - 58 - - - - - - - - - - - - - exhaust - min 50/60 mixed-flow wall mounting , ceiling mounting 0.03 220-240 1.5 21 100 IP 45 1850 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
max - - - - - - - - - - 0.66 - - - - - - - - - - - - - 93 - - - - - - - - - - - - - exhaust - max 50/60 mixed-flow wall mounting , ceiling mounting 0.04 220-240 2.7 26 100 IP 45 2650 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - 8 - - 25 mm expanded polypropylene counter-flow polystyrene - 130 - - - - - 82-94 - - - - - - - - - - - - - - - - - - - - 1 230 50/60 38 0.34 32 - 23...+40 G4 / Coarse > 60% G4 / Coarse > 60% (option F7 / ePM1 60%) 100 / 125 A+ - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - 8 - - 25 mm expanded polypropylene counter-flow enthalpy - 130 - - - - - 73-88 - - - - - - - - - - - - - - - - - - - - 1 230 50/60 38 0.34 32 - 23...+40 G4 / Coarse > 60% G4 / Coarse > 60% (option F7 / ePM1 60%) 100 / 125 A - - - - - - - - - - - - - - - - - - - - - -
60 m³/h - - - - - - - - - - - - - - - - 31 A+ - - aluzinc counter-flow polystyrene - - for round air ducts - - - - - - -25...+40 - 23 13 - - - - - - - flush mounting , wall mounting , ceiling mounting - - - - - - - 1 230 50/60 - - - - Coarse 90% / G4 ePM1 70% / F7 (G4 option) - - 58 0.5 160 2800 125 84-95 20 - - - - - - - - - - - - - - -
90 m³/h - - - - - - - - - - - - - - - - 31 A+ - - aluzinc counter-flow polystyrene - - for round air ducts - - - - - - -25...+40 - 34 26 - - - - - - - flush mounting , wall mounting , ceiling mounting - - - - - - - 1 230 50/60 - - - - Coarse 90% / G4 ePM1 70% / F7 (G4 option) - - 58 0.5 160 2800 125 84-95 20 - - - - - - - - - - - - - - -
160 m³/h - - - - - - - - - - - - - - - - 31 A+ - - aluzinc counter-flow polystyrene - - for round air ducts - - - - - - -25...+40 - 42 33 - - - - - - - flush mounting , wall mounting , ceiling mounting - - - - - - - 1 230 50/60 - - - - Coarse 90% / G4 ePM1 70% / F7 (G4 option) - - 58 0.5 160 2800 125 84-95 20 - - - - - - - - - - - - - - -
60 m³/h - - - - - - - - - - - - - - - - 31 A - - aluzinc counter-flow enthalpy - - for round air ducts - - - - - - -25...+40 - 23 13 - - - - - - - flush mounting , wall mounting , ceiling mounting - - - - - - - 1 230 50/60 - - - - Coarse 90% / G4 ePM1 70% / F7 (G4 option) - - 58 0.5 160 2800 125 74-89 20 - - 47-60 - - - - - - - - - - - -
90 m³/h - - - - - - - - - - - - - - - - 31 A - - aluzinc counter-flow enthalpy - - for round air ducts - - - - - - -25...+40 - 34 26 - - - - - - - flush mounting , wall mounting , ceiling mounting - - - - - - - 1 230 50/60 - - - - Coarse 90% / G4 ePM1 70% / F7 (G4 option) - - 58 0.5 160 2800 125 74-89 20 - - 47-60 - - - - - - - - - - - -
160 m³/h - - - - - - - - - - - - - - - - 31 A - - aluzinc counter-flow enthalpy - - for round air ducts - - - - - - -25...+40 - 42 33 - - - - - - - flush mounting , wall mounting , ceiling mounting - - - - - - - 1 230 50/60 - - - - Coarse 90% / G4 ePM1 70% / F7 (G4 option) - - 58 0.5 160 2800 125 74-89 20 - - 47-60 - - - - - - - - - - - -
60 m³/h - - - - - - - - - - - - - - - - 47 A+ - - aluzinc counter-flow polystyrene - - for round air ducts - - - - - - -25...+40 - 25 16 - - - - - - - ceiling mounting - - - - - - - 1 230 50/60 - - - - Coarse 90% / G4 ePM1 70% / F7 (G4 option) - - 58 0.5 160 2800 125 84-95 20 - - - - - - - - - - - - - - -
90 m³/h - - - - - - - - - - - - - - - - 47 A+ - - aluzinc counter-flow polystyrene - - for round air ducts - - - - - - -25...+40 - 35 26 - - - - - - - ceiling mounting - - - - - - - 1 230 50/60 - - - - Coarse 90% / G4 ePM1 70% / F7 (G4 option) - - 58 0.5 160 2800 125 84-95 20 - - - - - - - - - - - - - - -
160 m³/h - - - - - - - - - - - - - - - - 47 A+ - - aluzinc counter-flow polystyrene - - for round air ducts - - - - - - -25...+40 - 42 32 - - - - - - - ceiling mounting - - - - - - - 1 230 50/60 - - - - Coarse 90% / G4 ePM1 70% / F7 (G4 option) - - 58 0.5 160 2800 125 84-95 20 - - - - - - - - - - - - - - -
60 m³/h - - - - - - - - - - - - - - - - 47 A+ - - aluzinc counter-flow polystyrene - - for round air ducts - - - - - - -25...+40 - 25 16 - - - - - - - ceiling mounting - - - - - - - 1 230 50/60 - - - - Coarse 90% / G4 ePM1 70% / F7 (G4 option) - - 58 0.5 160 2800 125 84-95 20 - - - 4 800 - - - - - - - - - -
90 m³/h - - - - - - - - - - - - - - - - 47 A+ - - aluzinc counter-flow polystyrene - - for round air ducts - - - - - - -25...+40 - 35 26 - - - - - - - ceiling mounting - - - - - - - 1 230 50/60 - - - - Coarse 90% / G4 ePM1 70% / F7 (G4 option) - - 58 0.5 160 2800 125 84-95 20 - - - 4 800 - - - - - - - - - -
160 m³/h - - - - - - - - - - - - - - - - 47 A+ - - aluzinc counter-flow polystyrene - - for round air ducts - - - - - - -25...+40 - 42 32 - - - - - - - ceiling mounting - - - - - - - 1 230 50/60 - - - - Coarse 90% / G4 ePM1 70% / F7 (G4 option) - - 58 0.5 160 2800 125 84-95 20 - - - 4 800 - - - - - - - - - -
60 m³/h - - - - - - - - - - - - - - - - 47 A - - aluzinc counter-flow enthalpy - - for round air ducts - - - - - - -25...+40 - 25 16 - - - - - - - ceiling mounting - - - - - - - 1 230 50/60 - - - - Coarse 90% / G4 ePM1 70% / F7 (G4 option) - - 58 0.5 160 2800 125 74-89 20 - - 47–60 - - - - - - - - - - - -
90 m³/h - - - - - - - - - - - - - - - - 47 A - - aluzinc counter-flow enthalpy - - for round air ducts - - - - - - -25...+40 - 35 26 - - - - - - - ceiling mounting - - - - - - - 1 230 50/60 - - - - Coarse 90% / G4 ePM1 70% / F7 (G4 option) - - 58 0.5 160 2800 125 74-89 20 - - 47–60 - - - - - - - - - - - -
160 m³/h - - - - - - - - - - - - - - - - 47 A - - aluzinc counter-flow enthalpy - - for round air ducts - - - - - - -25...+40 - 42 32 - - - - - - - ceiling mounting - - - - - - - 1 230 50/60 - - - - Coarse 90% / G4 ePM1 70% / F7 (G4 option) - - 58 0.5 160 2800 125 74-89 20 - - 47–60 - - - - - - - - - - - -
60 m³/h - - - - - - - - - - - - - - - - 47 A - - aluzinc counter-flow enthalpy - - for round air ducts - - - - - - -25...+40 - 25 16 - - - - - - - ceiling mounting - - - - - - - 1 230 50/60 - - - - Coarse 90% / G4 ePM1 70% / F7 (G4 option) - - 58 0.5 160 2800 125 74–89 20 - - 47–60 4 800 - - - - - - - - - -
90 m³/h - - - - - - - - - - - - - - - - 47 A - - aluzinc counter-flow enthalpy - - for round air ducts - - - - - - -25...+40 - 35 26 - - - - - - - ceiling mounting - - - - - - - 1 230 50/60 - - - - Coarse 90% / G4 ePM1 70% / F7 (G4 option) - - 58 0.5 160 2800 125 74–89 20 - - 47–60 4 800 - - - - - - - - - -
160 m³/h - - - - - - - - - - - - - - - - 47 A - - aluzinc counter-flow enthalpy - - for round air ducts - - - - - - -25...+40 - 42 32 - - - - - - - ceiling mounting - - - - - - - 1 230 50/60 - - - - Coarse 90% / G4 ePM1 70% / F7 (G4 option) - - 58 0.5 160 2800 125 74–89 20 - - 47–60 4 800 - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - wall mounting , ceiling mounting - - - - - - - - - - - - - - - - - - - - - - - - - 165 Square - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - 47 - - - painted steel rotary aluminium - 270 - - - without heating - 75...92 - - - - - - - supply and exhaust with heat recovery - - - - wall mounting - - - - - - - 1 230 50/60 118 - 28 - G4 G4 , F7 - A - - - - - - - - - - - - 1.0 1800 -25 ... +40 125 20 mm, mineral wool - - - - -
- - - - - - - - - - - - - - - - - 48 - - - painted steel rotary aluminium - 270 - - - electric heating - 75...92 - - - - - - - supply and exhaust with heat recovery - - - - wall mounting - - - - - - - 1 230 50/60 818 4.0 28 - G4 G4 , F7 - A 118 1.0 - - - - - - - - - - - 1800 -25 ... +40 125 20 mm, mineral wool 700 3.0 - - -
- - - - - - - - - - - - - - - - - 100 - - 40 mm mineral wool polymer coated steel counter-flow polystyrene - 320 - - Wi-Fi , Filter replacement indication , Timer , Weekly schedule , External sensor connection without heating - 85-94 - - - - - - - - - - - - floor mounting - - - - - - - 1 230 50/60 - - 37 -25 ... +40 ISO Coarse >60% (G4)x2 ISO ePM1 60% (F7) - A 96 0.75 - - 200 - - - - - - - - - - - - - - 47 0.75 -
- - - - - - - - - - - - - - - - - 101 - - 40 mm mineral wool polymer coated steel counter-flow polystyrene - 320 - - Wi-Fi , Filter replacement indication , Timer , Weekly schedule , External sensor connection electric preheating - 85-94 - - - - - - - - - - - - floor mounting - - - - - - - 1 230 50/60 - - 37 -25 ... +40 ISO Coarse >60% (G4)x2 ISO ePM1 60% (F7) - A 96 0.75 - - 200 - - - - - - 1050 - - - - - - - 47 7 -
- - - - - - - - - - - - - - - - - 103 - - 40 mm mineral wool polymer coated steel counter-flow polystyrene - 320 - - Wi-Fi , Filter replacement indication , Timer , Weekly schedule , External sensor connection electric preheating , electric reheating - 85-94 - - - - - - - - - - - - floor mounting - - - - - - - 1 230 50/60 - - 37 -25 ... +40 ISO Coarse >60% (G4)x2 ISO ePM1 60% (F7) - A 96 0.75 - - 200 - - - - - - 1050 - - - - - - - 47 11 700
- - - - - - - - - - - - - - - - - 100 - - 40 mm mineral wool polymer coated steel counter-flow enthalpy - 320 - - Wi-Fi , Filter replacement indication , Timer , Weekly schedule , External sensor connection without heating - 73-89 - - - - - - - - - - - - floor mounting - - - - - - - 1 230 50/60 - - 37 -25 ... +40 ISO Coarse >60% (G4)x2 ISO ePM1 60% (F7) - A 96 0.75 - - 200 - - - - - - - - - - - - - - 47 0.75 -
- - - - - - - - - - - - - - - - - 101 - - 40 mm mineral wool polymer coated steel counter-flow enthalpy - 320 - - Wi-Fi , Filter replacement indication , Timer , Weekly schedule , External sensor connection electric preheating - 73-89 - - - - - - - - - - - - floor mounting - - - - - - - 1 230 50/60 - - 37 -25 ... +40 ISO Coarse >60% (G4)x2 ISO ePM1 60% (F7) - A 96 0.75 - - 200 - - - - - - 1050 - - - - - - - 47 7 -
- - - - - - - - - - - - - - - - - 103 - - 40 mm mineral wool polymer coated steel counter-flow enthalpy - 320 - - Wi-Fi , Filter replacement indication , Timer , Weekly schedule , External sensor connection electric preheating , electric reheating - 73-89 - - - - - - - - - - - - floor mounting - - - - - - - 1 230 50/60 - - 37 -25 ... +40 ISO Coarse >60% (G4)x2 ISO ePM1 60% (F7) - A 96 0.75 - - 200 - - - - - - 1050 - - - - - - - 47 11 700
- - - - - - - - - - - - - - - - - 139 - - 40 mm mineral wool polymer coated steel counter-flow polystyrene - 580 - - Wi-Fi , Filter replacement indication , Timer , Weekly schedule , External sensor connection without heating - 75-94 - - - - - - - - - - - - floor mounting - - - - - - - 1 230 50/60 - - 38 -25 ... +40 ISO Coarse >60% (G4)x2 ISO ePM1 60% (F7) - A 370 2.5 - - 250 - - - - - - - - - - - - - - 47 2.5 -
Share your opinion

Questionnaire
Please evaluate our updated site user friendliness