Login

Privacy Policy (GDPR)
Authorization
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Product consultation from our experts - Online
Registration
Signup
By using this form, you confirm that you have read the site terms of use Terms of use and completely accept the terms of use

VENTS 100 Wave One L

  • Description
  • Characteristics
  • Capacity diagram
  • Downloads
  • Modifications
  • Dimensions
  • Legend
Description
Description
APPLICATION
  • Permanent or intermittent extract ventilation of shower rooms, bathrooms, kitchens and other residential premises.
  • Ventilation of premises with high requirements to noise level.
  • Mounting into ventilation shafts or connection to Ø 100 mm air ducts.
DESIGN
  • Additional rubber seal realized by two-component molding allows the fans to be used in Zone 1.
  • Modern design and aesthetic look.
  • The casing, the impeller and the front panel are made of high-quality and durable UV-resistant plastic.
  • Advanced 7-blade aerodynamic profile of the mixed-flow impeller provides high air flow and pressure combined with low-noise operation.
  • The fan is equipped with a specially designed backdraft damper to prevent back flow and heat losses during the fan standby.
  • The fan exhaust spigot incorporates specially designed air rectifiers to reduce air turbulence, noise level and boost air pressure.
MOTOR
  • Reliable motor with low energy demand.
  • Rated for continuous operation and is completely maintenance-free.
  • Integrated overheating protection.
CONTROL

Automatic control:

  • Control with the electronic control unit BU-1-60. The control unit is supplied separately.
  • Control with the turn-off delay timer T. The built-in turn-off delay timer enables operation of the fan within 2 up to 30 minutes after turning the fan off with a switch.
  • Control with the timer T1. After turning of the external switch the turn-on delay timer is activated for 10 seconds up to 2 minutes. The fan remains turned off. After the fan is turned off with the external switch the fan keeps running within 2 up to 30 minutes according to the settings of the turn-off delay timer.
  • Control with the timer and humidity sensor TH. If the indoor humidity exceeds the set humidity point adjustable from 60% to 90%, the fan switches automatically on and runs until the indoor humidity drops below the set humidity point. After that the fan continues running according to the timer settings and turns off.

Manual control:

  • Manual operation with a room light switch (not included in the delivery set).
  • Operation with a built-in pull cord switch V. Not applicable in case of the ceiling mounting.
MOUNTING FEATURES
  • Direct installation inside a ventilation shaft.
  • Flexible air ducts may be used in case of remote location of the ventilation shaft. The air duct is connected to the exhaust spigot with a fixing clamp.
  • Wall mounting with screws.
  • Suitable for ceiling mounting.
MOUNTING EXAMPLE
Characteristics
Characteristics
Parameter VENTS 100 Wave One L
VENTS 100 Wave One T L
VENTS 100 Wave One T1 L
VENTS 100 Wave One TH L
VENTS 100 Wave One V L
Measurement unit
Voltage 220-240 220-240 220-240 220-240 220-240 V
Frequency 50 50 50 50 50 Hz
Power consumption 8 8 8 8 8 W
Air capacity 85 85 85 85 85 m³/h
Current 0.5 0.5 0.5 0.5 0.5 A
RPM 2100 2100 2100 2100 2100 min-1
Sound pressure level at 3 m 26 26 26 26 26 dBА
Weight 0.51 0.51 0.51 0.51 0.51 kg
Spigot size 100 100 100 100 100 mm
Design axial axial axial axial axial -
IP Code IP 44 Zone 1 IP 44 Zone 1 IP 44 Zone 1 IP 44 Zone 1 IP 44 Zone 1 -
Type exhaust exhaust exhaust exhaust exhaust -
Mounting wall mounting, ceiling mounting wall mounting, ceiling mounting wall mounting, ceiling mounting wall mounting, ceiling mounting wall mounting -
Capacity diagram
Capacity diagram
  • Selection method:
  • Air flow:
  • Pressure:
Operating point
  • Air flow: --
  • Pressure: ---
Files archieve
Downloads
Select document type
  • Advertising and printing products
  • Certificates
  • Technical documentation
Name
"VENTS Solid (One), VENTS Wave (One), VENTS Flip (One)" user's manual 11-2023 (V160EN-07) (pdf 1.77Mb)
"VENTS Wave One" product description 07-2023 (pdf 2.7Mb)
Download high quality image "VENTS Wave One" (psd 1.76Mb)
Download image "VENTS Wave One" for your website (png 357.86Kb)
"VENTS Solid (One), VENTS Wave (One), VENTS Flip (One) (120 V / 60 Hz)" user’s manual 07-2023 (V12060_160EN-07) (pdf 1.45Mb)
Modifications
Modification name Ball bearing motor Turn-off delay timer Turn-on delay timer Humidity sensor Pull-cord switch
VENTS 100 Wave One L - - - -
VENTS 100 Wave One T L - - -
VENTS 100 Wave One T1 L - -
VENTS 100 Wave One TH L - -
VENTS 100 Wave One V L - - -
+
+
+
+
+
Dimensions
Characteristics
VENTS 100 Wave One L
Parameter Value Measurement unit
Ø D 99 mm
B 160 mm
L 79 mm
L1 38 mm
Legend
Legend
PICTURE SYMBOL DESIGNATION MODIFICATION DESCRIPTION
Wave One L Modification with a ball bearing motor for long service life (around 40 000 operating hours). Installation at any angle is possible. The ball bearings require no maintenance and are greased for the entire service life.
Wave One T Modification with a regulated turn-on delay timer.
Wave One T1 Modification with a turn-on delay timer regulated from 10 seconds to 2 minutes and a turn-off delay timer regulated from 2 up to 30 minutes.
Wave One TH Modification with a turn-off delay timer regulated from 2 up to 30 minutes and a humidity sensor regulated from 60% up to 90%.
Wave One V Modification with a pull-cord switch.
Share your opinion

Questionnaire
Basic parameter for domestic fan selection