  • The unit is equippedf with a water or electric heater.

Air handling units with the air capacity up to 1500 m3/h in sound- and heat-insulated casing with integrated electric heater and rotary heat exchanger. Recuperating efficiency up to 85%. 

Voltage / frequency:

OK

Products in this series (5)

    • VUT R 400 EH EC

      VUT R 400 EH EC

      Maximum capacity - 400 m3/h.

      VUT R 700 EH EC

      VUT R 700 EH EC

      Maximum capacity - 700 m3/h.

      VUT R 900 EH EC

      VUT R 900 EH EC

      Maximum capacity - 900 m3/h.

      VUT R 1200 EH ЕС

      VUT R 1200 EH ЕС

      Maximum capacity - 1200 m3/h.

      VUT R 1500 EH ЕС

      VUT R 1500 EH ЕС

      Maximum capacity - 1500 m3/h.

    Series   Heat exchanger type   Rated air capacity [m3/h]   Heater type   Duct connection   Motor type   Control
    panel
    VENTS VUT
      R - rotary regenerator   400; 700; 900; 1200; 1500   E - electric   H - horizontal   EC - synchronous electronically commutated motor   А13
    Description

    The air handling units VUT R EH EC with an integrated electric heater are the ready-to-use ventilation units that provide air filtering, supply of fresh air to the premises and exhaust of stale extract air from the premises with synchronous thermal energy transfer from extract air flow to the supply air flow through the rotary heat exchanger. The VUT R models are used in ventilation and air conditioning systems installed in various premises that require reasonable energy saving solutions and controlled ventilation systems. EC motors reduce energy demand by 1.5-3 times and ensure high performance and low noise operation. All the models are designed for connection to Ø 160, 250 and 315 mm round air ducts.

    Modifications

    VUT R EH EC – models with electric heater.

    Casing

    The casing consists of a frame and three-layer 20 mm (VUT R 1500 – 25 mm) thick panels made of zinc aluminium internally filled with mineral wool for reliable heat- and sound-insulation.

    Due to the specially designed removable side panels the unit requires little service space and access to the unit components.

    Filter

    The unit has two filters G4 to filtrate intake and exhaust air. The unit can be supplied with F7 Intake filter (option).

    Motor

    The units are equipped with high-efficient direct current electronically-commutated (EC) motors with external rotor and backward curved impeller blades. Such motor design is the most progressive solution in energy saving. EC motors are featured with high performance and well controllable speed range. Premium efficiency reaching 90% is a definite advantage of electronically commutated motors.

    Rotary regenerator

    The rotary regenerator is a rotating short cylinder internally filled with corrugated aluminium band placed in such a way as to ensure passing of the supply and exhaust air streams through the rotary regenerator to exclude their direct contact. During rotation the band first comes in contact with supply air stream and then with extract air stream. The aluminium band is heated up and cooled down by turns and transfers the heat and moisture contained in the warm extract air to cold intake air stream from outside. As compared to a standard plate heat exchanger the rotary regenerator is featured with higher efficiency, ability to maintain indoor humidity and extremely low freezing danger which is nearly excluded in rated temperature and humidity conditions.

    Rotary regenerator operating logic

    Heater

    Electric heaters are used for application of the air handling unit at low outdoor temperatures. If heat recovery is not sufficient to reach the set supply air temperature, the air heater is turned automatically on and warms up the supply air flow. The heaters are equipped with protecting devices to ensure safe and reliable operation of the unit.

    Control and automation

    The unit is equipped with a built-in automation system and a multifunctional sensor control panel. The standard delivery set includes a 10 m cable for connection to the control panel.

    VUT R EH EC automation functions:
    • turning the unit on and off according to set parameters;
    • week-scheduled operation;
    • setting of the required supply air temperature and air flow with an external control panel;
    • actuating of air control dampers;
    • filter clogging control;
    • electric heating elements overheating protection (operating and emergency thermostats).
    Mounting

    The unit is designed for mounting to a horizontal plane, suspension to a ceiling or wall mounting by means of brackets. Service access must be provided on the side panel side, on the left from the supply air stream.

    E-mail

    Please, feel free to contact us.

    support@vents.ua

    Phohe

    Customer service.

    +380 44 406 36 25

    Online form

    Send a message center customer support.

    By using this form you confirm that you have read and agree with the site condition and terms.
    Send
    • SR series (round)

      SR series (round)

    • KOM series

      KOM series

    • VVG series (round)

      VVG series (round)

    • SRF series

      SRF series

    • C series

      C series

    • BELIMO TF230/TF24

      BELIMO TF230/TF24

    • BELIMO LF230/LF24

      BELIMO LF230/LF24

    • KRV series (round)

      KRV series (round)