VENTS TwinFresh Comfo RB-50
- Description
- Characteristics
- Downloads
- Dimensions
- Dimensions
- Accessories
Efficient, reliable and energy-saving ventilators TwinFresh Comfo 24 hours a day: | |
|
|
TWINFRESH VENTILATOR OPERATING LOGIC | |
Energy is recovered due to reversing operation of the ventilator, which consists of two cycles:
|
|
TWINFRESH COMFO CONTROL AND OPERATION MODES | |
|
|
|
|
VENTILATION SYSTEM ARRANGEMENT EXAMPLE BASED ON TWINFRESH VENTILATORS | |
|
|
Ventilation system arrangement example based on TwinFresh Comfo RB-50 ventilator |
|
TWINFRESH VENTILATOR DESIGN | |
The TwinFresh Comfo ventilators are equipped with automatic shutters. Fan is OFF (the automatic shutters are closed) Fan is ON (the automatic shutters are opened) The TwinFresh Comfo RB1-50 unit is equipped with a decorative front panel internally lined up with an insulation layer for extra sound attenuation and condensation prevention.
Two built-in filters with total filter class G3 are used to clean supply and extract air flows. The filters ensure fresh air cleaning of dust and insects and prevent the ventilator parts from soiling. The filters have antibacterial treatment. The filters are cleaned either with a vacuum cleaner or flushed with water with no harm to the antibacterial treatment. F8 filter is available as an option.
Round air ducts are made of PVC plastic. The telescope length is adjustable to the wall thickness which makes mounting quick and easy. |
The high-tech ceramic energy accumulator with regeneration efficiency up to 88 % is used for extract air heat energy recovery and supply air heating. Due to its cellular structure, the unique energy accumulator has larger air contact area and excellent heat conducting and accumulating properties. The ceramic energy accumulator has a special anti-bacterial treatment to prevent bacteria generation inside of the regenerator. The antibacterial treatment is rated for 10 years operation. The outer side of the regenerator is lined up with a heat insulating material.
Air is supplied or extracted by a reversible axial fan with DC motor with safe voltage 12 V. Due to DC technology the fan is distinguished with low energy demand. The motor has overheating protection and ball bearings for longer service life.
The specially designed outer hood enables removal of extract air flow and condensate that is generated inside of the outer hood from the building wall. Besides, the outer hood prevents ingress of water and foreign objects in the ventilator. The outer hood is internally covered with insulating material that absorbs street noise penetration into the room through the ventilator and prevents condensate generation in the outer hood. The EH 150 outer hood is made of polymer coated aluminium. The EH-2 150 outer hood for thin walls is made of polymer coated stainless steel. Due to its labyrinth structure of the outer hood air flow changes its direction several times and the ventilator is protected against direct wind impact.
The TwinFresh Comfo series models are equipped with a mounting plate which facilitates servicing of the fans, filters and the regenerator. The ventilation unit is fixed to the mounting plate with special magnets and contact sockets. The ventilator inner parts are accessible by pulling the ventilation unit by hand. |
INSTALLATION EXAMPLE | |
Installation into a wall with a standard thickness using the standard EH outer hood |
Installation into a thin wall using the EH-2 outer hood |
Angular installation with the NP 60x204-0021 mounting kit |
Parameter |
TwinFresh Comfo RB-50 1 speed |
TwinFresh Comfo RB-50 2 speed |
TwinFresh Comfo RB-50 3 speed |
Measurement unit |
---|---|---|---|---|
Speed | 1 | 2 | 3 | - |
Voltage | 100-230 | 100-230 | 100-230 | V |
Air flow | 21 (12) | 32 (19) | 50 (29) | m³/h (CFM) |
Phase | 1 | 1 | 1 | - |
Sound pressure level at 3 m distance | 13 (0.2) | 20 (0.4) | 23 (0.5) | dBA (sone) |
Current | 0.024 | 0.026 | 0.039 | A |
Unit power | 4.5 | 5 | 7 | W |
Transported air temperature | -20 (-4) ... +50 (112) | -20 (-4) ... +50 (112) | -20 (-4) ... +50 (112) | °С (°F) |
Frequency | 50/60 | 50/60 | 50/60 | Hz |
Outdoor sound pressure attenuation | 40 | 40 | 40 | dBА |
Regeneration efficiency | 88 | 83 | 75 | % |
Shutters | automatic | automatic | automatic | - |
Sound pressure level at 1 m distance | 22 (0.4) | 29 (0.7) | 32 (1) | dBA (sone) |
Functions | Filter replacement indication, Timer, Humidity sensor | Filter replacement indication, Timer, Humidity sensor | Filter replacement indication, Timer, Humidity sensor | - |
Remote control panel | - | - | - | - |
Duct | 150 | 150 | 150 | - |
Protection rating | IP 24 | IP 24 | IP 24 | - |
Parameter | Value | Measurement unit |
---|
Accessory image | Accessory name | Description | TwinFresh Comfo RB-50 | TwinFresh Comfo RB1-50 |
TwinFresh Comfo RB-50 completion kit | Completion kit: Accumulator; G3 filters; ventilation unit; mounting plate; control panel. | |||
TwinFresh Comfo RB1-50 completion kit | Completion kit: Accumulator; G3 filters; ventilation unit; mounting plate; control panel. | |||
EH white 150 | White painted aluminium outer hood | TwinFresh Comfo RB-50 | TwinFresh Comfo RB1-50 | |
EH chrome 150 | Polished stainless steel hood | TwinFresh Comfo RB-50 chrome | TwinFresh Comfo RB1-50 chrome | |
MVM 152 bVsn | Round stainless steel hood | TwinFresh Comfo RB-50-1 | TwinFresh Comfo RB1-50-1 | |
ЕН-2 grey 150 | Grey painted stainless steel outer hood for thin walls | TwinFresh Comfo RB-50-2 | TwinFresh Comfo RB1-50-2 | |
ЕН-2 chrome 150 | Polished stainless steel hood for thin walls | TwinFresh Comfo RB-50-2 chrome | TwinFresh Comfo RB1-50-2 chrome | |
MV 150 bVs | Round plastic grille | TwinFresh Comfo RB-50-3 | TwinFresh Comfo RB1-50-3 | |
NP 60х204-0021 | Angular mounting kit | TwinFresh Comfo RB-50-5 | TwinFresh Comfo RB1-50-5 | |
MVMO 150 bV1s An | Outer grille | TwinFresh Comfo RB-50-7 | TwinFresh Comfo RB1-50-7 | |
SF TwinFresh R50 G3 | G3 filter kit (2 pcs.) | |||
SF TwinFresh R50 F8 | G2 filter + F8 filter as a kit (1 pc.) | |||
RK TwinFresh Comfo R-50 | Control panel |